6. Adjust the support frame to the desired height

 

and secure with 8 screws. The length of the

 

support frame can be adjusted in steps of

 

3/4 ´´/ 20 mm from 15 3/16 ´´/ 386 mm to

 

25 7/16 ´´/ 646 mm (Fig. 21).

 

Note:

 

ensure that the minimum distance between the

 

hob and the extractor hood is maintained –

 

24 ´/ 600 mm for an electric hob and 30 ´/ 762 mm

 

for a gas hob

 

7. Stainless steel ventilation ducts only

 

(LK 590-010/020/030):

 

pull the protective film off the metal surface.

 

8. Place both ventilation ducts over the support

 

frame. Take care not to scratch the sensitive

 

duct surface.

 

9. Attach the electrical plug to the support frame

 

with sticky tape so that it can be easily reached

Fig. 21

later.

10. Hang the hood and the support frame with the

 

 

two key-holes to the two screws in the ceiling

 

(Fig. 22).

 

Attention: the two screws cannot support

 

the weight of the hood. Therefore it must be

 

supported at this stage!

Fig. 22

 

18

 

Page 8
Image 8
Gaggenau AH 590-720 manual Adjust the support frame to the desired height