6. Technical data / Settings table

6. Technical data / Settings table

Technical data (gas)

 

 

Burners:

Normal burner

 

 

 

Full burning

6500

BTU (1.90 kW)

 

Low burning

< 1400

BTU (0.41 kW)

 

High-intensity burner

 

 

Full burning

9500 BTU (2.8 kW)

 

Low burning

< 1900

BTU (0.56 kW)

Gas connection:

R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999, conical-cylindrical

Technical data, gas

Technical data (electrical)

Rated consumption

0.8 W

Voltage

AC 120 V

Frequency

60 Hz

Technical modifications reserved.

Countries

US

US

 

CA

CA

 

 

 

Gas family

Natural gas

Propane gas

Gas type

A

E

Pressure

6” W.C. (1.5 kPa)

10” W.C. (2.5 kPa)

 

 

 

A burner, full burning

0.94

0.74

A burner, low burning

0.49

0.36

 

 

 

B burner, full burning

1.28

0.87

B burner, low burning

0.58

0.42

 

 

 

 

 

 

∑ Power

32 000 BTU (9.4 kW)

32 000 BTU (9.4 kW)

∑ Consumption

0.9 m3/h

680 g/h