6. Technical data / Settings table
Technical data (gas) |
|
| |
Burners: | Normal burner |
|
|
| Full burning | 6500 | BTU (1.90 kW) |
| Low burning | < 1400 | BTU (0.41 kW) |
|
| ||
| Full burning | 9500 BTU (2.8 kW) | |
| Low burning | < 1900 | BTU (0.56 kW) |
Gas connection:
R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
Technical data, gas
Technical data (electrical)
Rated consumption | 0.8 W |
Voltage | AC 120 V |
Frequency | 60 Hz |
Technical modifications reserved.
Countries | US | US |
| CA | CA |
|
|
|
Gas family | Natural gas | Propane gas |
Gas type | A | E |
Pressure | 6” W.C. (1.5 kPa) | 10” W.C. (2.5 kPa) |
|
|
|
A burner, full burning | 0.94 | 0.74 |
A burner, low burning | 0.49 | 0.36 |
|
|
|
B burner, full burning | 1.28 | 0.87 |
B burner, low burning | 0.58 | 0.42 |
|
|
|
|
|
|
∑ Power | 32 000 BTU (9.4 kW) | 32 000 BTU (9.4 kW) |
∑ Consumption | 0.9 m3/h | 680 g/h |
12