4. Cleaning and care
Fig. 8
The grease filters must be cleaned on a regular basis (at the latest after 30 hours of operation). Overgreased filters are a fire risk!
Caution:
Avoid sharp and caustic cleaning agents as well as brushes and abrasive cleaners.
The stainless steel frontages must only be cleaned with a soft cloth.
Do not use any abrasive sponges either. Use commercially available window cleaner and apply it to a soft, moist cloth. Do not spray it onto the switch panel.
Clean the ventilation grille with a moist cloth and detergent solution. You should not clean the ventilation grille in a dishwasher because spots may appear on the ventilation grille.
Grease filter cleaning
You can clean the metal grease filters in a dishwasher at a maximum temperature of 65°C. Place the grease filter in the dishwasher with the opening pointing down to ensure that no food remainders will stay on it.
Proceed as follows: (fig. 8)
–Detach the ventilation grille.
–Turn up the two retaining wires and detach the grease filter from the appliance.
Insert in the reverse order.
5. Maintenance
Repairs must only be carried out by authorised specialists, thus ensuring the safety of the appliance. Improper tampering will render all warranty claims null and void.
First disconnect the appliance from the mains before carrying out any repairs.
In the event of malfunctions, first of all check the household fuses.
If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or your responsible Gaggenau