GB
5. Storage
Storage: | ➜ Clean and store the pump in a |
| frost arrives. |
Disposal: | The product must not be added to normal household waste. |
(in accordance with | It must be disposed of in line with local environmental regulations. |
RL2002/96/EC) |
|
6. Cleaning
Flushing the pump:
Cleaning the suction base and feed impeller:
s
The GARDENA should not require regular maintenance.
After pumping pumped chlorinated swimming pool water or other liquids leaving residues, the pump should be rinsed with clear water.
WARNING ! Electric shock !
Risk of injury due to electric shock.
➜Disconnect the pump from the mains before cleaning the suction base and feed impeller.
1.Unscrew the
2.6000 SP: Press snap hooks s together and remove safety cover from suction foot and clean.
3.Clean suction foot and impeller .
4.Refit suction foot and screw in the
5.6000 SP: Reinsert the safety cover in the suction foot again.
For safety reasons a damaged feed impeller can only be exchanged by the GARDENA Service Centre.
7. Troubleshooting
WARNING ! Electric shock !
Risk of injury due to electric shock.
➜Disconnect the pump from the mains before rectifying faults.
Problem | Probable cause | Remedy |
Pump is running, | Air cannot escape as | ➜ Open pressure line |
but oes not deliver. | pressure line is closed. | (e.g. kinked pressure pipe). |
|
|
|
| Air locks in the suction base. | ➜ Wait for max. 60 seconds |
|
| until the pump deaerates |
|
| automatically over the vent |
|
| valve. If necessary, switch |
|
| off and start it again. |
|
|
|
14