3. INSTALLATION

3.8 First start-up and calibration

Before the robotic lawnmower is operated, a start-up sequence in the robotic lawnmower's menu must be carried out as well as an automatic calibration of the guide signal. The calibration is also a good test to see that the installation of the guide wire has been done in such a way that the robotic lawnmower can easily follow the guide wire from the charging station.

1.Set the main switch to position 1.

2.Open the control panel cover by pressing the STOP button.

A start-up sequence begins when the robotic lawnmower is started for the first time. The following is requested:

Language

Time format

Current time

Date format

Date

Four digit PIN code. All combinations except 0000 are permitted.

IMPORTANT INFORMATION

Use Memo on page 4 to make a note of the

PIN code.

3.Place the robotic lawnmower in the charging station as requested in the display. Press the START button and close the cover. The robotic lawnmower will now start the guide calibration, by leaving the charging station and following the guide wire to the point where the guide wire is connected to the boundary wire to begin mowing there. Check that the robotic lawnmower can follow the guide wire all the way.

If it cannot, this may be due to an incorrectly installed guide wire. In this case, check that the installation is performed as described in

3.6Installation of the guide wire on page 28. Then carry out a new calibration. See 6.6 Settings on page 51.

In the case of the R70Li, it is also possible to reduce the guide width for the robotic lawnmower to follow the guide wire through very narrow passages. See 6.4 Installation, R70Li on page 45. Use the Test out function to carry out a new calibration in the R70Li. See 6.4 Installation, R70Li on page 45.

32 - English