Model | Int. Dimensions :In (mm) |
| Ext. Dimensions: In (mm) | Ship Wt | Ship Dim. | ||||
W | H | D | W |
| H ** | D (w/motor) | Lbs/kg | Cubic Ft. | |
|
| ||||||||
29 (736) | 24 (610) | 24 (610) | 38 (965) |
| 510/232 | 42 | |||
29 (736) | 24 (610) | 28 (711) | 38 (965) |
| 510/232 | 42 | |||
29(736) | 24(610) | 24(610) | 38(965) |
| 1024/464 | 84 | |||
29(736) | 24(610) | 28 (711) | 38(965) |
| 1024/464 | 84 | |||
|
|
|
|
|
|
|
|
|
|
**Height with or without standard casters. Height with low profile casters (double deck) is
Models | Input Ratings, Natural & Propane | Operating Pressure * | Electrical Specifications | |||||
BTU/hr | kW Equiv. | Gas Inlet | Natural | Propane | 120V/1Ph. | 240V/1Ph. | ||
| ||||||||
Single Deck | 60,000 | 17. 6 | (1 )@ 3/4" NPT | 4.5" WC | 10" WC | (1)@9.4A | (1)@ 5.2A | |
Double Deck | 120,000 | 35.2 | (1 )@1" NPT | (11 mbar) | (25 mbar) | (2)@9.4A | (2)@ 5.2A |
*Maximum Pressure 13.8" WC @ 70°F (21°C)
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes. These appliances are intended for commercial use by professionally trained personnel.
| 3/4" N.P.T. | 2" |
|
| 1" REAR | |||
GAS INLET | [51mm] |
| [32mm] |
| GAS INLET | |||
|
|
|
|
|
|
| ||
[197mm] |
|
|
|
|
|
|
| |
3/4" |
|
|
|
|
|
| ||
[19mm] | FLUE: |
|
|
| ||||
|
|
| [816mm] |
| ||||
“D” (includes | [60mm x 127mm] |
|
|
|
| [816mm] | ||
|
|
|
|
|
| |||
motor) |
|
|
|
|
|
| ||
| [972mm] |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
| [816mm] |
| |
|
|
|
|
|
|
| ||
|
| [816mm] |
| |||||
| [292mm] |
|
|
| [900mm] | |||
[451mm] |
|
|
|
|
|
| ||
| TOP VIEW |
|
|
|
|
| ||
|
|
|
|
| [375mm] |
| ||
| 38" | 3/4" REAR |
| DOUBLE DECK |
|
| ||
[965mm] |
|
|
| |||||
| [159mm] | FRONT VIEW |
|
| ||||
| GAS INLET |
|
|
| ||||
[32mm] |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
| Instillation Notes: |
| ||
|
|
| Combustible & | |||||
|
|
|
| Wall Clearances: |
| |||
[816mm] |
|
|
| Sides | 1" (25mm) | Back | 3" (76mm) | |
|
|
|
| |||||
|
|
| Entry Clearances: In (mm) | |||||
|
| [1386mm] | Crated | Uncrated | ||||
|
| 34" |
| |||||
|
| Notes: |
|
|
| |||
| [864mm] |
|
|
| ||||
[645mm] |
|
| 1. Standard electrical specifications include motor requirements. | |||||
| SINGLE DECK |
| 2. | (120V units) 115V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60Hz. | ||||
|
| 3. | (240V units) 200‑240V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60 Hz | |||||
| FRONT VIEW |
| ||||||
|
| 4. A 6 ft. line cord is provided for each 120V deck with a |
| |||||
|
|
|
| |||||
Gas Input Ratings shown here are for installations up to |
| (NEMA #5‑15P) plug. |
|
|
| |||
5. U. S. Range recommends a separate 15 AMP circuit for each 120V unit. | ||||||||
2,000 ft. (610m) above sea level. Specify altitudes over | ||||||||
|
|
|
|
| ||||
2,000 ft. |
|
|
|
|
| Form# SGM (06/07) | ||
|
|
|
|
|
| |||
Garland Commercial | Garland Commercial Ranges Ltd |
| Enodis UK LTD |
|
|
| ||
Industries, LLC | 1177 Kamato Road, |
|
| Swallowfield Way, |
|
|
| |
185 East South Street | Mississauga, Ontario |
|
| Hayes, Middlesex |
|
|
| |
Freeland, PA 18224 | L4W 1X4 CANADA |
|
| UB3 1DQ ENGLAND |
|
|
| |
Phone: (570) | Phone: |
| Telephone: |
|
|
| ||
Fax: (570) | Fax: |
|
| Fax: |
|
|
|