Pump Valves and Fittings
The 2.1 L pump can be connected to the hydraulic system using one of two methods. The five-connector method (page 8) uses the C1 ➊ and
C2 ➋ fittings to connect the pump to the cylinder and the H1 ➌ and H2 ➍ fittings to connect the pump to the helm. The three-connector method
(pages 5–7) uses only the H1 and H2 fittings, with a t-connector splitting the connection between the helm and cylinder. The return line fitting ➎ is used in both cases to connect to only the helm. The check valves ➏ do not need to be reconfigured if the boat is equipped with a balanced cylinder. If the boat is equipped with an unbalanced cylinder, the check valves must be reconfigured (page 3). The bypass valve ➐ is only opened for hydraulic bleeding, and must be fully tightened during normal operation.
➊
➌
➏
➎
➐ 
➋
➍
4 | 2.1 L Hydraulic Pump Installation Instructions |