1.Remove the hatch on the front of pedestal by loosening the screw and lifting the hatch off of the hinges as shown in Figure 1.
2.Using a 5 mm Allen wrench, install the M10 x 71 mounting studs (Figure 2) in the pedestal matching the hole pattern that was selected. Tighten the mounting studs until they bottom out in the pedestal. DO NOT overtighten the studs because this may cause damage to the pedestal. The mounting studs have a thread locking patch applied at the factory.
3.Install the Seals onto the pedestal (Figure 3).
Figure 1 | Figure 2 | Figure 3 |
The scanner can be mounted with either end pointed toward the bow as long as it is mounted along the
1.Determine a suitable mounting location and tape the Mounting Template in place. The Mounting Template has two hole patterns Option
A and Option B. Determine which pattern fits your mount or better suits your mounting location. Using a Center Punch, indent the center of each mounting hole. Using a 13 mm (1/2") bit, drill the four mounting holes. (This step is not necessary if you are using a
2.Hoist the scanner into position using the supplied strap. Position the strap over the ends of the antenna mount as shown in Figure 5. Make sure that the strap is positioned as close to the scanner as possible.
3.Fasten the scanner to the mounting surface using the M10 hex nuts, spring washers, and flat washers in the order shown in Figure 6.
The M10 nuts should be torqued to 130 in.lbs (11 ft.lbs) (1.5 kgf.m).
| Bearing Offset = 0° |
bow | stern |
Bearing Offset = 180°
Figure 4 | Figure 5 | Figure 6 |
flat washer
spring washer
M10 hex nut
GMR 404/406 Marine Radar Installation Instructions |