![](/images/backgrounds/239243/239243-176x1.png)
1.Remove the protective cover from the pedestal wave guide.
2.Verify that the antenna wave guide is aligned with the pedestal wave guide and slide the antenna onto the pedestal.
3.Secure the antenna to the pedestal using the 8 mm hex bolts and spring washers. The 8 mm bolts should be torqued to 70 in.lbs (6 ft.lbs) (.81 kgf.m).
align waveguide faces
Step Install the Voltage Converter UnitThe voltage converter requires an input voltage of
To scanner power cable
To ship’s power
15 Amp Slow Blow Fuse
To RF ground
Distance |
| Gauge |
3 meters (9.8 ft) |
| 12 AWG |
5 meters (16.4 ft) |
| 10 AWG |
6.5 meters (21.3 ft) |
| 9 AWG |
8 meters (26.2 ft) |
| 8 AWG |
Figure 7 |
|
Wire Gauge Table
GMR 404/406 Marine Radar Installation Instructions