2.0 L or 1.2 L Pump Hydraulic Layout on SeaStar Power Assist-Enabled Boats

Notes:

Power Assist module:

It may be necessary to remove the Power Assist module to gain access to the fittings, the hoses, and the bleed- tee fitting.

Remove the bleed-tee fitting from the

Power Assist module and relocate it to the return port on the pump.

2.0 L/1.2 L pump (and motor):

Install the pump to the steering lines between the cylinder and the Power Assist module.

Do not install the pump to the steering lines between the helm and the Power Assist module.

An unbalanced cylinder requires an unbalanced valve on the pump (See page 21)

Mount the pump horizontally if possible. Do not mount the pump vertically with the pump end (hydraulic connections) down.

Shadow Drive:

Starboard line

Return line

Port line

S R P

Helm

Bleed-tee fitting (relocate to the pump)

2.0L/1.2 L pump (and motor)

Shadow Drive

H1

H2

Sea Star

Power Assist

 

 

C1

C2

module

 

Return line

Mount the Shadow Drive horizontally and as level as possible.

Install the Shadow Drive in either the port or the starboard hydraulic steering line.

Always install a length of hose between the helm and the Shadow

Drive.

Do not install the Shadow Drive directly to the helm.

Install the Shadow Drive between the helm and the Power Assist module.

Port fitting

Starboard fitting

Do not install the Shadow Drive

Balanced cylinder

between the Power Assist module

 

and the pump.

 

Do not install the Shadow Drive between the Power Assist module and the cylinder.

notice

Do not turn the system on until you bleed all the air from the helm, the Shadow Drive, the pump, and all the hydraulic lines. See page 34.

GHP 10 Marine Autopilot System Installation Instructions

11