Advanced Configuration Power-on Procedure

Advanced configuration options are not available on the GHC 10 under normal conditions. To access the advanced configuration settings of the GHP 10, use the advanced configuration power-on procedure.

To access the wizards and advanced configuration options:

1.With the power off, press both the center and the right soft keys on the GHC 10.

2.While pressing the center and the right soft keys, power the GHC 10 on.

3.Press all 3 buttons until the heading screen appears. Release the buttons.

To make sure the wizards and advanced configuration options are available:

1.From the heading screen, select Menu > Setup.

2.If the option for Dealer Autopilot Configuration is available, you correctly performed the advanced configuration power-on procedure.

Hold these

and power the

soft keys

GHC 10 on

Advanced Configuration

Power-on Procedure

Manually Running the Dockside and Sea Trial Wizards

The Dockside Wizard and the Sea Trial Wizard allow you to quickly define all of the important configuration settings on the GHP 10. If, after running the wizards, you do not feel as though the GHP 10 is working correctly, you can run the wizards again at any time. To access the wizards, power the GHC 10 on using the advanced configuration power-on procedure.

To manually run the Dockside Wizard:

1.From the Heading screen, select Menu > Setup > Dealer Autopilot Configuration > Wizards > Dockside Wizard.

2.Perform the steps as prompted. For more information, see page 35.

To manually run the Sea Trial Wizard:

1.From the Heading screen, select Menu > Setup > Dealer Autopilot Configuration > Wizards > Sea Trial Wizard.

2.Perform the steps as prompted. For more information, see page 35.

Changing Advanced Configuration Settings

You can run the Autotune automated configuration process, calibrate the compass, and define north on the GHP 10 through the GHC 10 without running the wizards. Additionally, without running the wizards, you can individually define each configuration setting. To access the automated configuration settings and the advanced configuration settings, power the GHC 10 on using the advanced configuration power-on procedure

To manually run the automated configuration settings:

1.From the Heading screen, select Menu > Setup > Dealer Autopilot Configuration > Automated Setup.

2.Select Autotune, Calibrate Compass, or Set North.

3.Perform the steps as prompted. For more information on each automated configuration setting, see page 35.

To manually define individual configuration settings:

1.From the Heading screen, select Menu > Setup > Dealer Autopilot Configuration.

2.Select the appropriate category of setting you want to configure.

3.Select the setting you want to configure. Refer to the description of each setting on page 39.

38

GHP 10 Marine Autopilot System Installation Instructions