GarrettCom 84-00136 manual B5.0 Operation, B6.0 Ordering Information, B7.0 Troubleshooting

Models: 84-00136

1 73
Download 73 pages 8.22 Kb
Page 70
Image 70

Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

Note: The GND should be hooked up first. The 6K16-Series unit has a floating ground, so the user may elect to Ground either + or = terminal to suit the customer’s use.

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

An ON-OFF manual switch is optional for DC power. This can be used to cut off power connections and as a RESET for the Magnum 6K16-Series Switch.

B4.1 UL Requirements for DC-powered units

1.Minimum 18AWG cable for connection to a Centralized DC power source.

2.Minimum 14AWG cable for connection to a earthing wiring.

3.Use only with Listed 10 A circuit breaker provided in building installation.

4.“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

5.Fastening torque of the lugs on the terminal block: 9 inch-pound max.

6.Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block.

B5.0 OPERATION

Operation of Magnum 6K16-Series Switches with the optional -48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-powered models.

B6.0 ORDERING INFORMATION

To order the optional -48VDC power supply factory installed, add a suffix of “- -48VDC” after the product’s standard model # Example: Magnum 6K16-SeriesR-

48VDC.

Similarly to order the optional 24VDC or 125VDC industrial specific power supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s standard model #. Example: Magnum 6K16-Series- 24VDC, Magnum 6K16-Series- 125VDC.

B7.0 TROUBLESHOOTING

Please refer to Section 6.0 for troubleshooting

APPENDIX C: Internal DC Dual-Source Power Option

C1.0 SPECIFICATIONS - FOR MAGNUM 6K16-SERIES FIBER SWITCH

www . GarrettCom . com

62

Page 70
Image 70
GarrettCom 84-00136 manual B5.0 Operation, B6.0 Ordering Information, B7.0 Troubleshooting

84-00136 specifications

GarrettCom 84-00136 is a robust and reliable networking solution widely recognized for its versatility and performance in demanding environments. Specifically designed for industrial applications, the device excels in offering connectivity within harsh conditions, ensuring seamless communication across various network topologies.

One of the standout features of the GarrettCom 84-00136 is its high port density. With multiple Ethernet ports, it allows for extensive network connections, making it an ideal choice for facilities that require numerous devices to be interlinked. This capability ensures that organizations can efficiently manage their communication needs without compromising on performance.

Another significant characteristic of the 84-00136 is its industrial-grade durability. Built to withstand extreme temperatures, vibrations, and shocks, the device is suited for applications in manufacturing plants, transportation systems, and utility networks. This level of resilience is essential for maintaining reliable operations in environments where standard networking equipment might fail.

The technology behind the GarrettCom 84-00136 includes advanced switching capabilities. With support for both managed and unmanaged configurations, users can choose the level of control and customization that best fits their network requirements. The managed features allow for extensive monitoring and management, facilitating better network performance and security.

In addition, the 84-00136 supports various communication protocols, improving interoperability with existing systems. This flexibility is crucial for organizations looking to integrate new technologies into their established networks without overhauling the entire system.

Security is another critical aspect of the GarrettCom 84-00136. The device is equipped with robust security features, ensuring that network data remains protected from unauthorized access. This is particularly important in industrial environments where sensitive information must be safeguarded against potential cyber threats.

Ease of installation and maintenance is also a highlight of the GarrettCom 84-00136. Its user-friendly design allows for straightforward setup, minimizing downtime during deployment. Furthermore, ongoing maintenance is simplified through an intuitive interface, enabling quick troubleshooting and adjustments.

In summary, the GarrettCom 84-00136 is a high-performance networking solution tailored for industrial applications. Its impressive features, including high port density, industrial-grade durability, advanced switching capabilities, and robust security measures, make it an optimal choice for organizations seeking reliable and efficient network connectivity in challenging environments.