CSG14 Series Gigabit Converter Switch

Installation and User Guide (05/09)

3.8 Connecting Ethernet Media

The Magnum CSG14 Series Converter Switch can be connected to two media types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be used when making 1000BASE-T connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASE-FL, 100BASE-FX or 1000BASE-SX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.

Media

Twisted Pair (CAT 3 or 5) Twisted Pair (CAT 5)

Twisted pair (CAT5E or CAT6) Fiber (Multi-mode)

IEEE Standard

Connector

10BASE-T

RJ-45

100BASE-TX

RJ-45

1000BASE-T

RJ-45

10BASE-FL

SC

www . GarrettCom . com

55

Page 64
Image 64
GarrettCom CSG14U manual Connecting Ethernet Media, Ieee Standard