GE 2010 RAVRG2 AZ Series*-7500/8500, Return Air Grille, RAK5157/5207/5307†, RAK4157/4207/4307†

Models: 2010

1 24
Download 24 pages 36.64 Kb
Page 5
Image 5
RAVRG2 (AZ Series*—7500/8500)

RAVRG2 (AZ Series*—7500/8500)

Return Air Grille

Return air grille for installation in closet wall

Exterior dimensions 22-1/2" x 22-1/2"

Wall cutout dimension 20-3/8" x 20-3/8"

Accepts 20" x 20" x 1" field-supplied filter

Warm gray-beige color

RAK5157/5207/5307

(AZ Series*—7500 and 8500 only)

265/277-Volt Universal Power Supply Kit

9-pin connector with three 7" 12-gauge conductor wires.

 

 

 

Circuit

Kit No.

Volts

Heater Wattage

Ampacity

RAK5157

265/277

2.71 kw

15

RAK5207

265/277

3.55 kw

20

RAK5307

265/277

5.03 kw

30

RAK4157/4207/4307

(AZ Series*—7500 and 8500 only)

230/208-Volt Universal Power Supply Kit

9-pin connector with three 7" 12-gauge conductor wires.

 

 

 

Circuit

Kit No.

Volts

Heater Wattage

Ampacity

RAK4157

230/208

2,610/2,190

15

RAK4207

230/208

3,420/2,870

20

RAK4307

230/208

4,810/4,070

30

RAK3152/3202/3302

(AZ Series*—7500/8500 only)

15, 20, and 30 Amp (230/208 Volts)

Universal Power Supply

 

 

 

Circuit

Kit No.

Volts

Heater Wattage

Ampacity

RAK3152

230/208

2,610/2,190

15

RAK3202

230/208

3,420/2,870

20

RAK3302

230/208

4,810/4,070

30

*A-B Series: Zoneline units built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zoneline units built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ Series: Zoneline units built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 2900, 3800, 3900, 4100, 5800, 6100, 7500, 8500.

†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: 7,000 BTU models do not have 5,000-watt heaters. 5

Page 5
Image 5
GE 2010 manual RAVRG2 AZ Series*-7500/8500, Return Air Grille, RAK5157/5207/5307†, AZ Series*-7500and 8500 only