Installation Preparation
PREPARE ELECTRICAL WIRING
W ARNING
FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance.
Electrical Requirements
This appliance must be supplied with 120V, 60Hz., and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
Wiring must be 2 wire with ground.
If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
Grounding Instructions —– Cable Direct
This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance.
Grounding Instructions
W ARNING
The improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded.
Hole (Max.)
3"
from
Cabinet
24"
from Wall
Ground
Figure 5 | Black | White |
|
Cabinet Preparation & Wire Routing
The wiring may enter the opening from either side, rear or the floor within the shaded area.
Cut a
Cable direct connections may pass through the same hole as the drain hose and hot water line, if convenient. If cabinet wall is metal, the hole edge must be covered with a bushing. NOTE: Power cords with plug must pass through a separate hole.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher . For cable direct connections the cable must be routed as shown in Figure 5. Cable must extend a minimum of
24"from the rear wall.
For power cord connections, install a
4