Standard No. 53: Health Effects
Chemical Reduction Unit Lead and Atrazine Reduction Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction

Performance Data Sheet

SmartWater Filtration System

GWF / HWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*

(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Effluent

 

% Reduction

Min. Required

 

MCL

Challenge Concentration

Average

 

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

0.02 ppm

 

0.05 ppm

98.90%

97.37%

> 50%

T & O

 

Particulate**

at least 10,000 particles/mL

3,978

 

7,800

98.00%

96.10%

> 85%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Effluent

% Reduction

Min. Required

 

MCL

Challenge Concentration

Average

Maximum

Average

Minimum

Reduction

Turbidity

1 NTU***

11 + 1 NTU***

0.07 NTU

0.1 NTU

99.71%

99.59%

0.5 NTU

Cysts

99.95% Reduction

Minimum 50,000 L

26

55

99.97%

99.95%

> 99.95%

Lead at pH 6.5

15 ppb

0.15 mg/L + 10%

1 ppb

1 ppb

99.37%

99.37%

0.010 mg/L

Lead at pH 8.5

15 ppb

0.15 mg/L + 10%

1.8 ppb

4.3 ppb

98.8%

97.13%

0.010 mg/L

Lindane

0.0002 ppm

0.002 mg/L + 10%

0.00005 ppm

0.00005 ppm

91.93%

91.93%

0.0002 mg/L

Atrazine

0.003 ppm

0.009 mg/L + 10%

0.002 ppm

0.003 ppm

76.19%

64.28%

0.003 mg/L

2,4-D

0.100 ppm

0.210 mg/L + 10%

0.042 ppm

0.090 ppm

84.89%

67.63%

0.07 mg/L

Asbestos

99%

107 to 108 fibers/L;

0.32 MFL/ml

1.2 MFL/ml

99.95%

99.82%

99%

 

 

fibers greater than

 

 

 

 

 

 

 

10 micrometers in length

 

 

 

 

 

*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C

**Measurement in Particles/ml. Particles used were 0.5-1 microns

***NTU=Nephelometric Turbidity units

Operating Specifications

Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light; up to one year for models with a replacement filter indicator light

Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock

Temperature: 33–100ºF (0.6–38ºC)

Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.

Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

Check for compliance with the state and local laws and regulations.

Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Chemical Unit

Taste and Odor Reduction

Chlorine Reduction

Mechanical Filtration Unit

Particulate Reduction, Class I

NSF®

Manufactured for: General Electric Company, Louisville, KY 40225

27

Page 27
Image 27
GE 25, 20, 22 Performance Data Sheet, Operating Specifications, General Installation/Operation/Maintenance Requirements

22, 20, 25 specifications

The GE 25, officially known as the General Electric 25 (GE 25), is a revolutionary advanced gas turbine designed to enhance the efficiency and productivity of power generation. This cutting-edge turbine is engineered with an eye towards meeting the evolving demands of the energy market while ensuring environmental sustainability.

One of the primary features of the GE 25 is its highly efficient combustion process. Utilizing advanced combustion technology, the turbine achieves lower emissions of nitrogen oxides (NOx) while maintaining a high power output. The GE 25 is designed for use in both simple cycle and combined cycle power plants, making it a versatile choice for various energy generation applications. The turbine's ability to transition seamlessly between these cycles allows operators to optimize energy production based on demand.

The GE 25 is built with advanced materials that enhance durability and performance. The components are constructed from high-temperature alloys that withstand extreme operating conditions, thus ensuring longevity and lower maintenance costs. This durability is crucial as it minimizes downtime and maximizes productivity in power generation facilities.

Innovative technologies incorporated into the GE 25 include advanced aerodynamics and an intelligent control system. The turbine features an optimized blade design that improves airflow efficiency and reduces drag, resulting in higher overall performance. Additionally, the intelligent control system offers real-time monitoring and analysis, enabling predictive maintenance and ensuring that the turbine operates at peak efficiency.

The turbine's modular design simplifies installation and maintenance processes. This allows for faster commissioning times and enhances operational flexibility, making it a preferred choice for both new installations and retrofitting older plants. The GE 25 is also compatible with a wide range of fuel types, including natural gas, biogas, and even hydrogen blends, which aligns with the industry's shift towards more sustainable energy sources.

In summary, the GE 25 stands out as a powerhouse in the gas turbine industry, with its cutting-edge features, advanced technologies, and robust characteristics. By prioritizing efficiency, durability, and flexibility, the GE 25 meets the current and future energy needs while contributing to a greener planet. As the demand for reliable and sustainable energy sources continues to grow, the GE 25 will play a vital role in shaping the future of power generation.