6Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout,

attach the conduit and bring wires into the junction box. Leave 6″ of wire free at the end of the conduit to allow connections to be made.

Manual backgroundManual background Conduit

7If a fuse and fuseholder are to be used, the knockout at the top of the box is for mounting a Buss Fuseholder. Be sure the fuse and fuseholder are of the same rating as the branch circuit. Leadwires at the fuse can be either

soldered in place or attached using UL-listed 1/4″ female (receptacle) crimp connectors.

14

8Reinstall the junction box by engaging the tab at the lower rear, aligning the screw hole at the top and driving the one screw until secure. Be sure that all wire leads are inside the box and not pinched between the box and the chassis. The identified (ribbed) Neutral wire of the cordset MUST be connected to the white Neutral wire of the branch circuit. The green insulated ground wire from the chassis MUST be connected to the branch circuit ground wire.

9Make all wire connections by using appropriate UL-listed electrical connectors and techniques (black to black, white to white and green to green).

10Carefully tuck all wires and connections back inside the junction box. Be sure there are no loose connections or stray uninsulated wires exposed.

11Place the junction box cover in place. Replace the four screws removed earlier and tighten securely.

12Discard the unused portion of the plug and the cordset.