Before You Call For Service…
Troubleshooting Tips
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem | Possible Causes | What To Do | ||
Zoneline does |
| The unit is | • Make sure the Zoneline plug is pushed completely | |
not start |
| unplugged. | into the outlet. | |
|
|
|
|
|
|
| The fuse is blown/circuit | • Check the house fuse/circuit breaker box and replace | |
|
| breaker is tripped. | the fuse or reset the breaker. | |
|
|
|
|
|
|
| The unit is waiting for | • This is normal. The Zoneline will start again after | |
|
| the compressor overload | it resets. | |
|
| protector to reset. |
| |
|
|
|
|
|
|
| Power failure. | • If power failure occurs, set the mode control to STOP. | |
|
|
|
| When power is restored, set the mode control to the |
|
|
|
| desired setting. |
|
|
|
| • There is a protective time delay (up to 3 minutes) to |
|
|
|
| prevent tripping of the compressor overload. For this |
|
|
|
| reason, the unit may not start normal heating or cooling |
|
|
|
| for 3 minutes after it is turned back on. |
|
|
|
|
|
Zoneline does not cool |
| Indoor airflow | • Make sure there are no curtains, blinds or furniture | |
or heat as it should |
| is restricted. | blocking the front of the Zoneline. | |
|
|
|
|
|
|
| Outdoor airflow is | • Make sure the rear grille is not restricted. This can cause | |
|
| restricted or recirculated. | the unit to cycle off due to the compressor overload. | |
|
|
|
| • Outdoor grille must have a minimum of 65% free area. |
|
|
|
| |
|
|
|
| performance. Consult your salesperson for assistance. |
|
|
|
|
|
|
| The temp control may | • Turn the control to a lower or higher setting. | |
|
| not be set high enough. | NOTE: The temperature limiter may be limiting the temperature range. | |
|
|
|
| |
|
| The air filter is dirty. | • Clean the filter at least every 30 days. | |
|
|
|
| See the Operating Instructions section. |
|
|
|
|
|
|
| The room may have | • When the Zoneline is first turned on you need to | |
|
| been hot or cold. | allow time for the room to cool down or warm up. | |
|
|
|
| |
|
| Outdoor air is | • Set the vent control to the CLOSE position. | |
|
| entering the room. |
| |
|
|
|
| |
Burning odor at the start |
| Dust is on the surface | • This can cause a “burning” odor at the beginning of | |
of heating operation |
| of the heating element. | the heating operation. This odor should quickly fade. | |
|
|
|
| |
The air is not always |
| The heat pump is not | • This is normal. The heat pump will produce warm air | |
cool or hot during |
| producing hot air. | but not as hot as air produced when the | |
operation |
|
|
| electric heat is used. |
|
|
|
|
|
|
| The fan switch may be | • This causes the fan to blow room temperature air | |
|
|
| set at continuous fan | even when the compressor or heater cycles off. |
|
|
|
| The continuous air movement provides better |
|
|
|
| overall temperature control. |
|
|
|
| |
The air does not feel |
| The heat pump alone | • Use the Electric Heat Option. This turns off the | |
warm enough during |
| produces air that feels | heat pump and warms with electric heat only. | |
heating operation |
| cooler than desired. | NOTE: Use of this option will result in increased energy | |
|
|
|
| consumption. |
|
|
|
|
20