Before You Call For Service…

Troubleshooting Tips

Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem

Possible Causes

What To Do

Zoneline does

 

The unit is

Make sure the Zoneline plug is pushed completely

not start

 

unplugged.

into the outlet.

 

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

 

The unit is waiting for

This is normal. The Zoneline will start again after

 

 

the compressor overload

it resets.

 

 

protector to reset.

 

 

 

 

 

 

 

 

Power failure.

If power failure occurs, set the mode control to STOP.

 

 

 

 

When power is restored, set the mode control to the

 

 

 

 

desired setting.

 

 

 

 

There is a protective time delay (up to 3 minutes) to

 

 

 

 

prevent tripping of the compressor overload. For this

 

 

 

 

reason, the unit may not start normal heating or cooling

 

 

 

 

for 3 minutes after it is turned back on.

 

 

 

 

 

Zoneline does not cool

 

Indoor airflow

Make sure there are no curtains, blinds or furniture

or heat as it should

 

is restricted.

blocking the front of the Zoneline.

 

 

 

 

 

 

 

Outdoor airflow is

Make sure the rear grille is not restricted. This can cause

 

 

restricted or recirculated.

the unit to cycle off due to the compressor overload.

 

 

 

 

Outdoor grille must have a minimum of 65% free area.

 

 

 

 

Non-GE grilles may be too restrictive for proper

 

 

 

 

performance. Consult your salesperson for assistance.

 

 

 

 

 

 

 

The temp control may

Turn the control to a lower or higher setting.

 

 

not be set high enough.

NOTE: The temperature limiter may be limiting the temperature range.

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days.

 

 

 

 

See the Operating Instructions section.

 

 

 

 

 

 

 

The room may have

When the Zoneline is first turned on you need to

 

 

been hot or cold.

allow time for the room to cool down or warm up.

 

 

 

 

 

 

Outdoor air is

Set the vent control to the CLOSE position.

 

 

entering the room.

 

 

 

 

 

Burning odor at the start

 

Dust is on the surface

This can cause a “burning” odor at the beginning of

of heating operation

 

of the heating element.

the heating operation. This odor should quickly fade.

 

 

 

 

The air is not always

 

The heat pump is not

This is normal. The heat pump will produce warm air

cool or hot during

 

producing hot air.

but not as hot as air produced when the higher-cost

operation

 

 

 

electric heat is used.

 

 

 

 

 

 

 

The fan switch may be

This causes the fan to blow room temperature air

 

 

 

set at continuous fan

even when the compressor or heater cycles off.

 

 

 

 

The continuous air movement provides better

 

 

 

 

overall temperature control.

 

 

 

 

The air does not feel

 

The heat pump alone

Use the Electric Heat Option. This turns off the

warm enough during

 

produces air that feels

heat pump and warms with electric heat only.

heating operation

 

cooler than desired.

NOTE: Use of this option will result in increased energy

 

 

 

 

consumption.

 

 

 

 