1.When Receiving a Z-Wave Dim Command - Parameter 7 (number of steps or levels)

- Parameter 8 (timing of the steps) - Length: 1 Byte

Valid Values:

Parameter 7 (default = 1) Valid Values: 1-99

Parameter 8 (default = 3) Valid Values: 1-255

2.Manual Control Dimming (pressing the Dimmer’s rocker) - Parameter 9 (number of steps or levels)

- Parameter 10 (timing of the steps) - Length: 1 Byte

Valid Values:

Parameter 9 (default = 1) Valid Values: 1-99

Parameter 10 (default = 3) Valid Values: 1-255

3.When Receiving an All-On or All-Off Command - Parameter 11 (number of steps or levels)

- Parameter 12 (timing of the steps) - Length: 1 Byte

Valid Values:

Parameter 11 (default = 1) Valid Values: 1-99

Parameter 12 (default = 3) Valid Values: 1-255

Ignore Start Level When Receiving Dim Commands Please note: Every “Dim” command includes a start level embedded in it.

The 45606 can be set to ignore the start level that is part of the dim command. Setting parameter 5 to a value of 0 will cause the 45606 to dim or brighten from the start level embedded in the command.

-Parameter No: 5

-Length: 1 Byte

-Valid Values = 0 or 1 (default 1)

Page 16