Zoneline® units

RAK4157/4207/4307

(AZ Series*—2800, 3800, 5500, 5800 and 7500 only)

230/208-Volt Universal Power Supply Kit

9-pin connector with three 7" 12-gauge conductor wires.

 

 

 

Circuit

Kit No.

Volts

Heater Wattage

Ampacity

RAK4157

230/208

2,550/2,090

15

RAK4207

230/208

3,450/2,820

20

RAK4307

230/208

5,000/4,090

30

RAK3152/3202/3302

(AZ Series*—7500 only)

15, 20, and 30 Amp (230/208 Volts)

Universal Power Supply

 

 

 

Circuit

Kit No.

Volts

Heater Wattage

Ampacity

RAK3152

230/208

2,550/2,090

15

RAK3202

230/208

3,450/2,820

20

RAK3302

230/208

5,000/4,090

30

RAK3153/3203/3303

(AZ Series*—2800, 3800, 5500 and 5800 only) 15, 20, and 30 Amp (230/208 Volts)

Universal Power Supply with LCDI

 

 

 

Circuit

Kit No.

Volts

Heater Wattage

Ampacity

RAK3153

230/208

2,550/2,090

15

RAK3203

230/208

3,450/2,820

20

RAK3303

230/208

5,000/4,090

30

RAK4002 (AZ Series*—2200, 3200 and 5200 only)

Direct Connect Junction Box

(230/208 and 265/277 Volts)

RAK4002 junction box kit for permanent connection of 230/208- and 265/277-volt units to building power supply.

Includes multi-circuit connector harness for use on value line units. Junction box is included on 265/277-volt units.

RAK4002A (AZ Series*—2500, 2800, 3500 and 3800 only)

Direct Connect Junction Box

(230/208 and 265/277 Volts)

RAK4002 junction box kit for permanent connection of 230/208- and 265/277-volt units to building power supply.

Includes multi-circuit connector harness for use on value line units. Junction box is included on 265/277-volt units.

*A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.

†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent connection kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.

12