GE ACUXL16 manual Configuration, Description, Belden Cable Number or equal, Max. Distance

Models: ACUXL16

1 4
Download 4 pages 27.91 Kb
Page 3
Image 3
Configuration

Configuration

Cable #

Description

Belden Cable Number ( or equal)

Max. Distance

1

Communication (RS-485)

#9842 or Alpha #6222C, 24 AWG, 2-pair, braid overall shield AND #9409 or

4,000’ (1,220 m) 4,000’

Power (24 VDC)

Alpha #1897C, 18 AWG, 2-conductor/unshielded

(1,220 m)

 

2

Exit Request Button / Sensor

#9407-22 AWG, 2-conductor (unshielded)

1,000’ (305 m)

Input

 

 

 

3

Door Lock Control from

#9409-18 AWG, 2-conductor (unshielded)

1,000’ (305 m)

Controller or RRE

 

 

 

4

Standard Reader

Varies with type of reader/keypad. See manufacturers instructions.

varies

Controller to Host

5Communication or other ACU panels OR Controller to 10/100 Hub Communication

#9842 or Alpha #6222C, 24 AWG, 2-pair/braid overall shield #1583A-24 AWG,

4,000’ (1,220 m) 328’

4-pair (unshielded)

(100 m)

Page 3
Image 3
GE ACUXL16 manual Configuration, Description, Belden Cable Number or equal, Max. Distance