Before You Call For Service…

Troubleshooting Tips

Save time and money! Review the chart on this page first and you may not need to call for service.

Problem

 

Possible Causes

What To Do

 

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

 

is unplugged.

into the outlet.

 

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

 

Power failure.

If power failure occurs, turn the mode control to OFF.

 

 

 

 

When power is restored, wait 3 minutes to restart the

 

 

 

 

air conditioner to prevent tripping of the compressor

 

 

 

 

overload.

 

 

 

 

 

 

 

The current interrupter

Press the RESET button located on the power

 

 

device is tripped.

cord plug.

 

 

 

 

If the RESET button will not stay engaged, discontinue

 

 

 

 

use of the air conditioner and contact a qualified

 

 

 

 

service technician.

 

 

 

 

Air conditioner does

 

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

 

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

 

The temp control may

Turn the knob to a higher number. The highest setting

 

 

not be set high enough.

provides maximum cooling.

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days. See the Care and

 

 

 

 

cleaning of the air conditioner section.

 

 

 

 

 

 

 

The room may have been hot.

When the air conditioner is first turned on you need to

 

 

 

 

allow time for the room to cool down.

 

 

 

 

 

 

 

Cold air is escaping.

Check for open furnace floor registers and cold

 

 

 

 

air returns.

 

 

 

 

Set the air conditioner’s vent to the closed position.

 

 

 

 

 

 

 

Cooling coils have iced up.

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner

 

Ice blocks the air flow

Set the mode control at HIGH FAN or HIGH COOL with

freezing up

 

and stops the air conditioner

the temp at 1 or 2. Wait for approximately one hour,

 

 

from cooling the room.

then reset to desired temperature.

 

 

 

 

 

Consumer Support

Normal Operating Sounds

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

The fan may run even when the compressor does not.

14

Page 14
Image 14
GE AGX08, AGX10 owner manual Before You Call For Service…, Consumer Support Normal Operating Sounds

AGX10, AGX08 specifications

The GE AGX10 and AGX08 represent cutting-edge advancements in industrial solutions, tailored for diverse applications in automation and control systems. These two models showcase a commitment to efficiency, versatility, and durability, making them highly sought after in sectors like manufacturing, energy, and transportation.

One of the most notable features of the GE AGX10 is its robust processing power. Equipped with a high-performance CPU, the AGX10 can handle complex computations and data processing with ease. This capability allows users to execute intricate algorithms and real-time analytics, providing insights crucial for operational optimization. The AGX08, while slightly less potent, still delivers commendable processing capabilities suitable for less demanding applications, ensuring reliability without compromising performance.

Both models boast advanced connectivity options, including Ethernet, USB, and serial interfaces. This wide array of connectivity enhances interoperability with other devices and systems, enabling seamless integration into existing setups. The use of industrial Ethernet protocols ensures high-speed communication and reduced latency, making them ideal for real-time control environments.

In terms of technology, the GE AGX10 and AGX08 are equipped with state-of-the-art safety features, adhering to international standards. These safety protocols are essential in preventing accidents and ensuring the protection of both personnel and equipment. The systems can detect possible faults or malfunctions and can execute preventive measures to mitigate risks.

Another significant characteristic is their rugged design. Built to withstand harsh industrial environments, both the AGX10 and AGX08 feature robust housings, making them resistant to dust, moisture, and extreme temperatures. This durability not only extends their operational lifespan but also reduces maintenance costs, providing significant value to users.

Flexibility is a hallmark of both models, allowing for easy customization to meet specific industry needs. Users can integrate additional software modules and hardware components, tailoring the systems to fit unique operational requirements. This adaptability is further complemented by user-friendly interfaces that simplify configuration and programming.

In conclusion, the GE AGX10 and AGX08 are emblematic of the next generation of industrial automation solutions. With their powerful processing capabilities, extensive connectivity options, robust safety measures, and rugged designs, these models are well-equipped to meet the demanding needs of today’s dynamic industrial landscape. Their commitment to reliability and performance ensures they remain at the forefront of technology in automation and control systems.