GE AHRSO About the controls on the dehumidifier, OtherFeatures, OPower Pad, Display, Delay Off

Models: AHR30 AHW40 AHR40 AHR65 AHWSO AHW65 AHH40 AHW30 AHRSO

1 24
Download 24 pages 27.54 Kb
Page 4
Image 4
About the controls on the dehumidifier.

About the controls on the dehumidifier.

4 houror2 hour

High,Medklm

Cleanthe Filter

Continuousoperationon

BucketFulllightindicates

delayoff

and Lowfan

indicatorlight

indicatorlight

bucketneedstobeemptied

indicatorlights

indicatorlights

 

 

orisnotinplaceintheunit

Humidity %

4hour

2hour

/VOTE'._'_hen the bucket is tull or removed, the

conti'olsControlscannot be set.

OPower Pad

Press to turn the dehumidifier on and oil

OFilter Timer

After 250 hours of operation, the Clean the Filter indicator light MII gl()_ to remind you to clean the filtei: Remove the filter and clean it.

Press to turn off the Clean the Filterlight. See the Care and Cleaning section.

Conti

'u

m

ous

Bucket Full

 

PowerOn

Clean the Filter

indicatorlight

ling

 

When you fi_st use the dehumidifie_; set the humidity control to 45% or 50%. Mlow

at least 24 l_otu_ fi)r the dehumidifier to achieve the humidity level. If you still have damper air than desired, set t'he humidiQ'

level to a lower setting or select ContintlOtlS

for maximum dehumidification.

0 Display

Sho_s the set % humidity level _dfile setting, then shows the actual (+/- 5%

accm'ac)) room % humidity lmel.

@Humidity Set Control Pads

The humidiff level can be set within a range of 35% RH (Relative Humidity) to 80% RH

(Relative Humidity) in 5% increments or at

COfi)r continuous operation.

/VOTE'.If CO (Continuous) is selected, the

dehumidifier will operate continuously at

its maMm um dehumidification settings if attached to a hose to drain or until the

bucket is flfll.

For drier ai_; press the pad and set to a lower percent vahle (%).

For damper ai_; press the pad and set to a higher percent vahle (%).

O Fan Speed Pad

Controls the tim speed.

Press to select either High, Medium or Low fan speed.

Set the tim control to Highfor maximum

moisture remowfl. When the humidity

has been reduced and quiet operation is

preferred, set the fan control to Medium or Low.

0 Delay Off

%hile the dehumidifier is in operation,

press this pad to set it to automatically mrn off in 2 hom_ or 4 hom_.

OtherFeatures

BUCKETFULLLight

(;lows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper position.

Alarm

]f the bucket is fifll or missing tbr more than three minutes, an alarm will sound filr about l 0 seconds

 

to remind

you to

erupt}

and replace the

bucket.

 

Auto Shut Off

 

 

 

 

4

The Water

I,evel

Control

Switch shuts

off'the

dehumidifier

 

when the

bucket is fifll,

or when

the bucket is removed or not replaced in the proper position.

Auto Defrost

%l_en fix)st builds up on the evaporator coils,

the compressor will cycle off and the tim will

continue to rtm until the fi'ost disappears.

Power Outage

In the case of a power outage or interruption,

the unit will automatically re-start, in the settings last used, after the power is restored.