Before you call for service…

Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.

Problem

 

Possible Causes

What To Do

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed

does not start

 

is unplugged.

completely into the outlet.

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

Power failure.

If power failure occurs, turn the air conditioner OFF.

 

 

 

When power is restored, wait 3 minutes to restart the

 

 

 

air conditioner to prevent tripping of the compressor

 

 

 

overload.

 

 

 

 

Air conditioner does

 

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may

Turn the temperature knob to a higher number.

 

 

not be set correctly.

 

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days.

 

 

 

See the Operating Instructions section.

 

 

 

 

 

 

The room may have been hot.

When the air conditioner is first turned on, you need to

 

 

 

allow time for the room to cool down.

 

 

 

 

 

 

Cold air is escaping.

Check for open furnace floor registers and cold

 

 

 

air returns.

 

 

 

Set the air conditioner’s vent to the closed position.

 

 

 

 

 

 

Cooling coils have iced up.

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner

 

Ice blocks the air flow

Set the mode control at HIGH FAN or HIGH COOL with

freezing up

 

and stops the air conditioner

the temp at 1 or 2.

 

 

from cooling the room.

 

 

 

 

 

Water drips outside

 

Excessively hot and

This is normal.

 

 

humid weather.

 

 

 

 

 

Water drips indoors

 

The air conditioner is not

For proper water disposal, make sure the air conditioner

 

 

tilted to the outside.

slants slightly from the case front to the rear.

 

 

 

 

Water collects in

 

Moisture is removed from

This is normal for a short period in areas with little

base pan

 

indoor air and drains into

humidity; normal for a longer period in very humid

 

 

rear of a cabinet where a fan

areas.

 

 

blows it against the outdoor

 

 

 

condenser coil.

 

Normal Operating Sounds

You may hear a pinging noise caused by

Water will collect in the base pan during

water being picked up and thrown against the

high humidity or on rainy days. The water

condenser on rainy days or when the humidity is

may overflow and drip from the outdoor side

high. This design feature helps remove moisture

of the unit.

and improve efficiency.

The fan may run even when the compressor

 

You may hear the thermostat click when the

does not.

compressor cycles on and off.

 

13

Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support

Page 13
Image 13
GE ASP05 owner manual Before you call for service…, Normal Operating Sounds

ASP05 specifications

The GE ASP05 and AST06 are advanced electronic systems that represent the cutting edge of technology in various applications, particularly in the fields of automation, control, and monitoring. These devices are part of General Electric’s commitment to providing efficient and reliable solutions for industrial operations.

The GE ASP05 is known for its robust architecture, designed to withstand harsh environments while delivering exceptional performance. It features a high-speed processor that enables faster data processing and response times, making it ideal for real-time applications. Its modular design allows for scalability, enabling businesses to customize their systems according to specific needs. The ASP05 supports multiple communication protocols, ensuring interoperability with various devices and systems, which is crucial for seamless integration in industrial setups.

On the other hand, the GE AST06 is a specialized model that focuses on advanced sensor technologies. It employs state-of-the-art sensing techniques that enhance the accuracy and reliability of data collection. The AST06 is equipped with advanced algorithms that facilitate predictive maintenance, reducing downtime and maintenance costs. Its user-friendly interface allows operators to easily access data and insights, promoting informed decision-making.

One of the standout features of both models is their built-in security measures. GE has prioritized cybersecurity in the design of the ASP05 and AST06, incorporating multiple layers of protection to safeguard critical data and operations from potential threats. This is particularly important in today's digital landscape, where industrial systems are increasingly vulnerable to cyberattacks.

Additionally, both models are designed with energy efficiency in mind. They are capable of optimizing energy consumption without compromising performance, aligning with global sustainability goals. This focus on energy efficiency not only reduces operational costs but also contributes to a lower environmental impact.

In conclusion, the GE ASP05 and AST06 are testament to GE's commitment to innovation and excellence in electronic systems. With their advanced features, robust design, and emphasis on security and efficiency, they are well-suited for a variety of industrial applications. These models exemplify the future of automation and control, driving productivity and performance in a rapidly evolving technological landscape. Businesses looking to enhance their operations will find that the GE ASP05 and AST06 offer substantial benefits that are difficult to overlook.