Troubleshooting Tips…

Troubleshooting Tips: Save time and money!

Problem

 

Possible Causes

What To Do

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed

does not start

 

is unplugged.

completely into the outlet.

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

Power failure.

If power failure occurs, turn the air conditioner OFF.

 

 

 

When power is restored, wait 3 minutes to restart the

 

 

 

air conditioner to prevent tripping of the compressor

 

 

 

overload.

 

 

 

 

Air conditioner does

 

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may

On models with touch pads: In COOL mode, press the

 

 

not be set correctly.

DECREASE pad.

 

 

 

On models with control knobs, turn the temperature

 

 

 

knob to a higher number.

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days.

 

 

 

See the Operating Instructions section.

 

 

 

 

 

 

The room may have been hot.

When the air conditioner is first turned on, you need

 

 

 

to allow time for the room to cool down.

 

 

 

 

 

 

Cold air is escaping.

Check for open furnace registers and cold air returns.

 

 

 

Set the air conditioner’s vent to the closed position.

 

 

 

 

 

 

Cooling coils have iced up.

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner

 

Ice blocks the air flow

On models with control knobs, set the mode control

freezing up

 

and stops the air conditioner

at HIGH FAN or HIGH COOL with the temp at 1 or 2.

 

 

from cooling the room.

On models with touch pads, set the controls at

 

 

 

HIGH FAN or HIGH COOL and set the thermostat to

 

 

 

a higher temperature.

 

 

 

 

The remote control is

 

The batteries are inserted

Check the position of the batteries. They should be

not working

 

incorrectly.

inserted in the opposite (+) and (–) direction.

 

 

 

 

 

 

The batteries may be dead.

Replace the batteries.

 

 

 

 

Water drips outside

 

Hot, humid weather.

This is normal.

 

 

 

 

Water drips indoors

 

The air conditioner is not

For proper water disposal, make sure the air conditioner

 

 

tilted to the outside.

slants slightly from the case front to the rear.

 

 

 

 

Water collects in

 

Moisture removed from air

This is normal for a short period in areas with little

base pan

 

and drains into base pan.

humidity; normal for a longer period in very humid areas.

 

 

 

 

“E1” appears

 

Function error code.

Unplug the air conditioner. Wait 3 minutes and plug it

in the display

 

 

back in.

 

 

 

 

TIMER or SLEEP feature

 

A power outage or interruption

In the case of a power outage or interruption, the unit

not working properly

 

occurred.

TIMER and SLEEP features will reset to the original setting.

 

 

 

You may need to set a new time if desired.

 

 

 

 

Consumer

Normal Operating Sounds

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

16You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

The fan may run even when the compressor does not.

Page 16
Image 16
GE ASW24, ASW18, ASV24, ASN24, ASM24, ASF24, ASL24, ASQ24 Troubleshooting Tips…, Consumer, Normal Operating Sounds

ASQ24, ASL24, ASF24, ASM24, ASN24 specifications

General Electric (GE) has made a significant impact in the industrial automation market with its range of programmable logic controllers (PLCs) tailored for various applications. Among these models, the ASQ24, ASN24, ASL24, ASV24, and ASW24 stand out for their unique features, technologies, and characteristics that cater to diverse operational needs.

The ASQ24 model is known for its versatility in handling complex automation tasks. This PLC integrates advanced communication capabilities, allowing seamless connectivity with other devices in an industrial network. It features robust processing power and enhanced memory capacity, enabling it to execute sophisticated algorithms and manage extensive I/O operations efficiently.

Moving to the ASN24, this model is specifically designed for applications requiring high-speed data processing and real-time control. Equipped with specialized functions to manage motion control and automation seamlessly, the ASN24 excels in environments with stringent timing requirements. Its compatibility with various communication protocols ensures it can interface easily with existing systems, enhancing interoperability within manufacturing operations.

The ASL24 model focuses on safety and reliability. Complying with international safety standards, the ASL24 comes equipped with built-in safety features designed to mitigate risks in industrial operations. This model also allows for easy diagnostics and system monitoring, making maintenance straightforward. This PLC is ideal for applications where equipment safety and operational integrity are paramount.

The ASV24 enhances visualization and user interaction with robotic applications. It incorporates advanced human-machine interface (HMI) technology, allowing operators to monitor and control processes intuitively. The ASV24 is designed to facilitate data visualization and analytics, providing insights into operational efficiency and performance metrics.

Lastly, the ASW24 is tailored for wireless applications, making it suitable for operations in remote or mobile environments. This model supports wireless communication networks, permitting real-time monitoring and control without traditional cabling constraints. The ASW24 is perfect for scenarios where flexibility and ease of deployment are prioritized.

In summary, the GE ASQ24, ASN24, ASL24, ASV24, and ASW24 PLCs represent a comprehensive suite of automation solutions. With their unique features, such as enhanced safety, high-speed processing, intuitive visualization, and wireless capabilities, these models cater to the diverse needs of modern industrial operations, making them essential tools for optimizing productivity and efficiency across various sectors.