AZ39H12DAC
GE Zoneline® Deluxe Series Heat Pump Unit
Dimensions and Installation Information (in inches)
Electrical Wiring
All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult a qualified electrician.
Grille Options |
| Wall Case Dimensions | |||
Stamped Aluminum Grille – RAG60 | |||||
|
|
| |||
Exterior Architectural Louvers Durable Polycarbonate: |
|
|
| ||
RAG61 (Beige) | RAG63 (Bittersweet) |
|
|
| |
| A |
| |||
RAG62 (Maple) | RAG67 (Extruded Aluminum) |
|
| ||
|
|
|
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps. RAK40 – Deflector Kit to adapt chassis for use with existing exterior architectural louvered grilles.
Ducted Applications
2900 and 3900 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box and require direct
connection. (NEC Requires 265V Direct Connection) See Architects and Engineers Design Data Manual for electrical
connection information including use of
Power Connection kits required on all Zoneline chassis.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
Maximum Cord Extension
21 | 58 |
RAB71 Wall Sleeve
C
RAB77 Wall Sleeve
Molded SMC
B A –
Wall Opening Dimensions
Add 1/4" to A and C dimensions for all
RAB71
RAB71 available in 16", 24", 28" and 31" depths
RAB77
230/208 Volt Line Cord Connected Units |
|
| ||
|
|
|
| Min. Circuit |
Line Cord | Electric Heat | Electric | Electric | Protection |
Kit | (Btuh) | Heater Watts | Heat Amps | (Amps) |
RAK3153 | 8,600/7,100 | 2,550/2,090 | 11.6/10.6 | 15 |
RAK3203 | 11,700/9,600 | 3,450/2,820 | 15.5/14.1 | 20 |
RAK3303 | 17,000/13,900 | 5,000/4,090 | 22.3/20.3 | 30 |
|
|
|
|
|
230/208 Volt |
|
| ||
|
|
|
| Min. Circuit |
| Electric Heat | Electric | Electric | Protection |
(Btuh) | Heater Watts | Heat Amps | (Amps) | |
RAK204D15P | 8,600/7,100 | 2,550/2,090 | 11.6/10.6 | 15 |
|
|
|
|
|
RAK204D20P | 11,700/9,600 | 3,450/2,820 | 15.5/14.1 | 20 |
|
|
|
|
|
RAK204D30P | 17,000/13,900 | 5,000/4,090 | 22.3/20.3 | 30 |
|
|
|
|
|
| Specification Created 2/08 | 390584 |