TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSES | REMEDIES |
|
|
|
High operating pressure | Recycle or concentrate valve | Disassemble the plumbing to the |
| plugged | recycle valve and remove for- |
|
| eign particles. Check the con- |
|
| centrate valve stem. |
|
|
|
| Inaccurate pressure gauge | Replace or calibrate the gauge as |
|
| required. |
|
|
|
| Restricted or reduced permeate | See possible causes for low per- |
| flow rate | meate rate. |
|
|
|
Excessive pressure drop | Restricted flow after pump | Check for blockage of the con- |
[over 50 psig (3.4 barg)] | outlet | centrate flow at the inlets and |
(high primary pressure - low |
| outlets of membrane element |
final pressure) |
| housings. |
|
|
|
| Telescoped membrane element | Ensure that the |
| covering membrane element | (ATD) is located properly on the |
| housing outlet port | membrane element. |
|
|
|
| Severely fouled or dirty | Flush the machine, then clean it |
| membrane elements | with detergent. |
|
|
|
Water flowing when machine is | Inlet solenoid valve not closing | Clean or replace the valve. |
turned OFF | or seating properly | Clean the membrane elements |
|
| with detergent immediately. |
|
| Water must not pass through the |
|
| inlet when the machine is OFF. |
|
|
|
Declining rejection | Dirty or fouled membrane ele- | Flush and clean the membrane |
(high permeate conductivity) | ments | elements. |
|
|
|
28