Specification summary*

Ordering Information

Description

Wattage

Colour

Product Code

 

 

 

 

CMH20/T/UVC/U/830/G8.5 Plus

20

3000K

39858

CMH35/T/UVC/U/830/G8.5 Plus

35

3000K

43273

CMH35/TC/UVC/U/842/G8.5

35

4200K

26348

CMH70/TC/UVC/U/830/G8.5 Plus

70

3000K

43274

CMH70/T/UVC/U/942/G8.5

70

4200K

26349

 

 

 

 

General

Units

20W

35W

35W

70W

70W

3000K

3000K Plus

4200K

3000K Plus

4200K

 

 

 

 

 

 

 

Product code

 

39858

43273

26348

43274

26349

Nominal Wattage

W

20

35

35

70

70

Format

 

 

 

Single ended

 

 

Bulb type

 

T4.5

T4.5

T4.5

T4.5

T4.5

Bulb diameter

mm

14.5

14.5

14.5

14.5

14.5

Bulb material

 

 

 

UVC Quartz

 

 

Bulb finish

 

 

 

Clear

 

 

Arc Gap

mm

3.35

4.65

4.3

7.4

5.5

Base

 

G8.5

G8.5

G8.5

G8.5

G8.5

 

 

 

 

 

 

 

Operating Conditions

 

 

 

 

 

 

Burning position

 

 

 

Universal

 

 

Luminaire characteristics

 

 

 

Enclosed

 

 

Notes:

1)Lamp voltage in the luminaire should not increase by more than 5V when compared to lamp voltage in free air.

2)Ballast protection required, according to IEC61167.

3)35W & 70W data is based on operation from a conventional magnetic ballast. Improved performance can be achieved using an electronic ballast.

4)35W 4200K CMH lamp is based on operation from an electronic ballast. Lamps can run on conventional ballast with a small reduction in performance.

5)20W designed for operation only from an electronic ballast.

Electrical Characteristics *

Lamp power

W

20

39

39

72

72

Lamp voltage

V

90

90

90

90

90

Lamp current

A

0.226

0.50

0.50

0.98

0.98

Max. Ignition Voltage

kV

***

5.0

5.0

5.0

5.0

Min. Ignition Voltage

kV

***

3.5

3.5

3.5

3.5

Extinction voltage

%

***

90 (Max.)

90 (Max.)

90 (Max.)

90 (Max.)

(% of rated input voltage)

 

 

 

 

 

 

*The specification provides typical performance data for 35W & 70W operating from a 50Hz mains sinewave supply at nominal power. Actual values depend on ballast, supply voltage and application 20W to be used only with an electronic ballast

*** See additional notes on electronic ballast requirements for 20W

Specification summary*

Photometric Characteristics

 

20W

35W

35W

70W

70W

 

3000K

3000K Plus

4200K

3000K Plus

4200K

Product code

 

39858

43237

26348

43274

26349

100 hrs Lumens

lm

1650

3400

3150

6200

6000

Typical Lumen change

 

 

 

 

 

 

with burning position

lm

 

 

100-150

 

 

– vertical to horizontal

 

 

 

 

 

 

Typical voltage change

 

 

 

 

 

 

with burning position

V

 

 

8

 

 

– vertical to horizontal

 

 

 

 

 

 

Correlated Colour Temperature

K

3000

3000

4200

3000

4200

Chromaticity X

 

0.435

0.435

0.475

0.435

0.475

Chromaticity Y

 

0.400

0.400

0.370

0.400

0.370

Colour Rendering Index

Ra

80+

84+

88+

80+

90+

Luminous efficacy

lm/W

85

86

80

86

83

Base

 

 

 

G8.5

 

 

 

 

 

 

 

 

Starting and Warm-up Characteristics*

 

 

 

 

 

Time to start ( at 25 °C )

sec.

< 2

< 2

< 2

< 2

< 2

Time to start - Cold box test at -30 °C

sec.

< 2

< 2

< 2

< 2

< 2

Hot restart time

min.

< 3

< 3

15

15

15

Warm-up time (for 90% lumens)

min.

1.2

1.2

3

3

3

* Typical values (actual values are ballast and ignitor dependent)

Through life Performance*

Lumen maintenance

%

68

68

85

71

77

at 40% rated life (mean lumens)

 

 

 

 

 

 

Average rated life

h

12000

15000

12000

15000

15000

* Life data measured in Vertical Base up position. Performance can be greatly increased in horizontal position.

Maximum Operating temperatures**

Maximum allowed bulb temperature

 

 

 

 

 

 

(horizontal orientation, thermocouple

°C

500

500

500

550

550

attached above burner)

 

 

 

 

 

 

Maximum pinch temperature

°C

300

300

300

300

300

(vertical base up orientation)

 

 

 

 

 

 

*The specification provides typical performance data for 35W & 70W operating from a 50Hz mains sinewave supply at nominal power. Actual values depend on ballast, supply voltage and application 20W to be used only with an electronic ballast – see later for additional notes on electronic ballast requirements.

** Temperatures above which lamp performance or reliability is impaired. Additionally, voltage rise when operated in luminaire should not exceed 5V

*** Photometric characteristics refer to lamp performance after 100hrs burning.

2

3

Page 2
Image 2
GE G8.5 brochure Specification summary

G8.5 specifications

The GE G8.5 is a revolutionary imaging system that represents a significant advancement in medical technology. It is designed primarily for the healthcare sector, integrating cutting-edge features and innovative technologies to enhance diagnostic capabilities and improve patient outcomes.

One of the standout features of the G8.5 is its high-resolution imaging capability. The system is equipped with advanced imaging sensors that capture images in remarkable detail, allowing clinicians to make accurate assessments quickly. The high-resolution images enable better visualization of smaller anatomical structures, making it easier to diagnose various conditions during imaging procedures.

Another key characteristic of the GE G8.5 is its user-friendly interface. Designed with healthcare professionals in mind, the interface provides an intuitive experience that streamlines workflow. Clinicians can easily navigate through different settings, make adjustments on the fly, and access patient data without any hassle. This improves efficiency, allowing healthcare providers to focus more on patient care rather than being bogged down by complex technology.

In addition to its imaging capabilities and user interface, the G8.5 features advanced connectivity options. This includes seamless integration with hospital information systems and electronic medical records. As a result, it supports better data sharing among medical professionals and enhances collaboration in patient care. Clinicians can access medical histories, previous imaging results, and consult with colleagues in real-time, further elevating the quality of care provided.

Furthermore, the GE G8.5 incorporates artificial intelligence (AI) technologies that assist in image analysis and interpretation. These AI-driven features enhance diagnostic accuracy and reduce the potential for human error. The system can automatically detect anomalies, suggest relevant parameters, and even prioritize images for review, significantly speeding up the workflow and enabling practitioners to make informed decisions.

Lastly, the GE G8.5 is built to meet stringent safety and regulatory standards, ensuring that it offers not only advanced technology but also reliability and patient safety. With its durable design and high-quality components, it is engineered for long-term use in busy medical environments.

In conclusion, the GE G8.5 is a state-of-the-art imaging system endowed with high-resolution capabilities, a user-friendly interface, advanced connectivity, AI integration, and a commitment to safety. These features position it as a vital tool in modern healthcare, ready to transform the landscape of medical imaging and diagnostics.