Chapter 16 Wireless System

Wireless Specifications

Zone Transceiver II Specifications

ITEM

 

SPECIFICATIONS

• ZT II U

 

 

Output Power

 

6.8 mW

Type of Interface

 

U Interface

Number of Simultaneous Speech Path

 

Maximum 3

Power Supply

 

• PBX Power Supply (DC –48 V)

 

 

• Local Power Supply (AC 100 V/200 V)

Power Consumption

 

Maximum 3 W

Operating Conditions

 

Ambient Temperature: –10 50 °C

 

 

Relative Humidity : 45 - 85 % (non-condensing)

 

 

Installation Location : Indoor

Dimensions (unit: mm)

 

160 (W) x139 (D) x40 (H) (Excluding Antenna)

Weight

 

Approx. 400 g

 

Wire Diameter

 

 

 

26 AWG

 

 

24 AWG

 

 

22 AWG

 

 

19AWG

 

 

 

 

2W

 

 

2500 ft.

 

 

4000 ft.

 

 

5500 ft.

 

 

8000 ft.

 

 

PBX Power

 

 

 

(762 m)

 

 

(1219 m)

 

 

(1676 m)

 

 

(2438 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply at -48 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4W

 

 

4300 ft.

 

 

6900 ft.

 

 

9500 ft.

 

 

13000 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1310 m)

 

 

(2103 m)

 

 

(2895 m)

 

 

(3958 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2W

 

 

2000 ft.

 

 

3200 ft.

 

 

4700 ft.

 

 

7000 ft.

 

 

PBX Power

 

 

 

(609 m)

 

 

(975 m)

 

 

(1432 m)

 

 

(2131 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply at -45 V

 

4W

 

 

3500 ft.

 

 

5600 ft.

 

 

8200 ft.

 

 

12200 ft.

 

 

 

 

 

 

(1066 m)

 

 

(1706 m)

 

 

(2499 m)

 

 

(3718 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2W

 

 

1800 ft.

 

 

2900 ft.

 

 

4400 ft.

 

 

6400 ft.

 

 

PBX Power

 

 

 

(548 m)

 

 

(883 m)

 

 

(1340 m)

 

 

(1948 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply at -43 V

 

4W

 

 

3100 ft.

 

 

5000ft.

 

 

7600 ft.

 

 

11000 ft.

 

 

 

 

 

 

(944 m)

 

 

(1524 m)

 

 

(2316 m)

 

 

(3352 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Local Power Supply

 

 

11000 ft.

 

 

13000 ft.

 

 

13000 ft.

 

 

13000 ft.

 

 

 

 

(3350 m)

 

 

(3958 m)

 

 

(3958 m)

 

 

(3958 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System Capacity

 

 

 

 

 

 

 

Capacity

 

 

 

 

 

 

Description

Integrated

 

Adjunct (Analog)

 

Adjunct (CCIS)

 

 

 

1PIM

2PIM

3PIM

 

4PIM

 

5PIM

 

6PIM

7PIM

8PIM

Zone Transceiver (ZT)

16

32

48

 

64

 

80

96

112

128

Dterm PS Note

 

 

 

 

 

 

512

 

 

 

 

 

CSI

 

4CSIA-A

 

 

 

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSH

 

 

 

 

 

 

 

24

 

 

 

 

 

PS Simultaneous Connections

 

 

 

 

 

216

 

 

 

 

 

Calling Area

 

 

 

 

 

 

32

 

 

 

 

 

ZT per Calling Area

 

 

 

 

 

128

 

 

 

 

 

Note: All existing CSH cards in a system should be SPN-SC03B 8CSH-C (AP) when accommodating 257 or more PSs.

UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide

Page 16-15

Issue 6

 

Page 337
Image 337
NEC 2000 IPS manual Wireless Specifications, Zone Transceiver II Specifications, Integrated Adjunct Analog Adjunct Ccis