Chapter 5 Station Equipment
Page 5- 14 UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide
Issue 6
Dterm Series E Line Conditions
Loop Resistance and Distance (Long Loop circuit built-in)
Line Card Terminal Maximum
Loop Resistance ()
Cable Length
(24 AWG Cable)
(Without ACA Unit)
Cable Length
(24 AWG Cable)
(With ACA Unit)
DTP-8-1 TEL 35 1000 ft. (304 m) 4000 ft. (1219 m)
DTP-8D-1 TEL 35 1000 ft. (304 m) 4000 ft. (1219 m)
DTP-16D-1 TEL 26 650 ft. (198 m) 4000 ft. (1219 m)
DTP-32D-1 TEL 21 650 ft. (198 m) 4000 ft. (1219 m)
4DLC
DCU-60-1 Console N/A N/A 1000 ft. (304 m)
DTP-8-1 TEL 35 1000 ft. (304 m) 1000 ft. (304 m)
DTP-8D-1 TEL 35 1000 ft. (304 m) 1000 ft. (304 m)
DTP-16D-1 TEL 26 650 ft. (198 m) 1000 ft. (304 m)
DTP-32D-1 TEL 21 650 ft. (198 m) 1000 ft. (304 m)
8DLC
DCU-60-1 Console N/A N/A 1000 ft. (304 m)
DTP-8-1 TEL 35 2800 ft. (853 m) 4000 ft. (1219 m)
DTP-8D-1 TEL 35 2800 ft. (853 m) 4000 ft. (1219 m)
DTP-16D-1 TEL 26 2800 ft. (853 m) 4000 ft. (1219 m)
DTP-32D-1 TEL 21 2800 ft. (853 m) 4000 ft. (1219 m)
2DLCB/N
DCU-60-1 Console N/A N/A 2800 ft. (853 m)