Chapter 3 System Highlights

Transmission Characteristics (For TDM Circuits)

Description

Specifications

PCM Coding System

A-law/U-law

Insertion Loss

0.15 dB at 1KHz

Return Loss

20 dB or more (300 to 3,400Hz) against 600 ohms

Longitudinal Balance

59 dB or more (300 to 3,400Hz)

Attenuation/Frequency Distortion

-0.2 dB to +0.7 dB (300 to 3,400Hz)

Group Delay Distortion

0 to 0.3msec. (500 to 2,800 Hz)

Total Distortion

25 dB (Input signal:-45 dBm0)/40 dB(input signal:0 dBm0)

Idle Channel Noise

-67 dBmop or less (psophometric noise)

 

-50 dBm0 or less (single frequency noise)

Impulsive Noise

0 counts at -35 dBm

Cross Talk Attenuation

90 dB or more

Inter-modulation Products

-40 dB or more

Spurious In-Band Signals

-49 dBm0 or less

Signal Attenuation

Attenuation rate: 12 dB per octave or more at 3.4 kHz above

 

Attenuation level: -40 dBm or less at 3.4 kHz and above

 

-70 dBm or less at 50 kHz and above

Line Conditions

 

Description

Specifications

Loop Resistance (including Telephone Set)

Analog Standard Line

 

Max. 600 ohms

Analog Long Line

 

Max. 2,500 ohms (DP 10pps), Max. 1,700 ohms (DP 20pps)

 

 

 

Max. 1,200 ohms (DTMF)

Loop Resistance (including Opposite End Resistance)

Central Office Trunk

 

Max. 1,700 ohms

Tie Line Trunk (Loop Dial)

Max. 2,500 ohms

Tie Line Trunk (E&M)

 

Max. 900 ohms (only E-wire condition)

Cable Length

Note 1

 

SN716 Desk Console

 

 

 

8DLC/4DLC/2DLC Card

Max. 350 meters (Max. 300 meters for 8DLC card)

 

4DLC/2DLC Card with

Max. 1,200 meters

 

AC Adapter

 

Dterm Series

i/E

 

 

 

8DLC/4DLC Card

Max. 200 meters (Max. 300 meters for Dterm 8 and Dterm 8D)

 

2DLC Card

Max. 850 meters

 

4DLC/2DLC Card with

Max. 1,200 meters

 

AC Adapter

 

DSS/BLF Console

 

 

 

4DLC/2DLC Card with

Max. 1,200 meters

 

AC Adapter

 

Zone Transceiver

 

 

 

ZTII-U (for U-Interface)

Max. 1,210 meters (2-wire), Max. 2,100 meters (4-wire) @-48V

 

 

 

Max. 970 meters (2-wire), Max. 1,700 meters (4-wire) @-45V

 

ZTII-U with AC Adapter

Max. 3,950 meters

Note 1: Cable length is based on cable with 0.5mm diameter and without lightning arresters

UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide

Page 3-17

Issue 6

 

Page 65
Image 65
NEC 2000 IPS manual Transmission Characteristics For TDM Circuits, Line Conditions, Cable Length