Chapter 3 System Highlights
UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide Page 3-19
Issue 6
Multi-frequency Compelled (MFC) – R2 SIGNAL
(1) MFC Frequency Value
Frequencies Forward Signals(Hz) Backward Signals(Hz)
F0 1,380 1,140
F1 1,500 1,020
F2 1,620 900
F3 1,740 780
F4 1,860 660
F5 1,980 540
(2) MFC Combinations
Combination Number Frequencies
1 F0 + F1
2 F0 + F2
3 F1 + F2
4 F0 + F3
5 F1 + F3
6 F2 + F3
7 F0 + F4
8 F1 + F4
9 F2 + F4
10 F3 + F4
11 F0 + F5
12 F1 + F5
13 F2 + F5
14 F3 + F5
15 F4 + F5
(3) Sender/Receiver Specifications
Description Specifications
Sender
Sender Transmitted Level -8 dbm to -11.5 dBm
Frequency Variation +/- 2 Hz
Receiver
Sensitivity Range -35 dBm to 0 dBm
Frequency Variation +/- 12 dBm