Audible Tones and Ringing Signal

Audible Tones

Tone

Frequency

 

Interruption

Dial Tone (DT)

350 Hz mixed with 440 Hz

Continuous

Special Dial Tone (SDT)

350 Hz mixed with 440 Hz

0.125 sec. ON, 0.125 sec. OFF

Busy Tone (BT)

480 Hz mixed with 620 Hz

0.5 sec. ON, 0.5 sec. OFF

Reorder Tone (ROT)

480 Hz mixed with 620 Hz

2.5 sec. ON, 0.25 sec. OFF

Howler Tone (HWT)

2,400 Hz interrupted by 16 Hz

Continuous

Service Set Tone (SST)

350 Hz mixed with 440 Hz

Continuous

Ring Back Tone (RBT)

440 Hz mixed with 480 Hz

1 sec. ON, 3 sec. OFF

Hold Tone (HDT)

480 Hz mixed with 620 Hz

0.25 sec. ON, 0.25 sec. OFF

 

 

 

0.25 sec. ON, 1.25 sec. OFF

Second Dial Tone

440 Hz mixed with 480

Hz

0.25 sec. ON, 0.25 sec. OFF

 

 

 

0.25 sec. ON, 1.25 sec. OFF

Call Waiting Ring back Tone

440 Hz mixed with 480

Hz

1 sec. ON, 1 sec. OFF

Message Waiting Indication Tone

350 Hz mixed with 440

Hz

0.125 sec. ON, 0.125 sec. OFF

Ringing Signal

Description

Specifications

Frequency

20 or 25Hz

Voltage

75 or 90Vrms

Note: The IPS has the capability to detect the above type of signal from Central Office and to transmit the above type of signal to PBX stations.

Dimension and Weight

UNIVERGE NEAX 2000 IPS

 

 

Description

 

 

Specifications

 

 

 

 

 

Dimensions (W x D x H; mm)

 

 

Weight (kg)

 

 

 

 

 

 

 

 

 

 

 

Main Equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIM (Fully card-mounted)

 

Approx. 430 x 223 x 353

 

 

Approx. 11.5

 

 

 

BASE

 

Approx. 430 x 205.2 x 61.6

 

 

Approx. 3.0

 

 

 

BASE TRAY (for UL)

 

Approx. 435 x 224.6 x 66.2

 

 

Approx. 1.7

 

UNIVERGE NEAX IPS DM/IPS DML/IPS DMR

 

 

 

 

 

 

Description

 

 

Specifications

 

 

 

 

 

Dimensions (W x D x H; mm)

 

 

Weight (kg)

 

 

 

 

 

 

 

 

 

 

 

Main Equipment

 

 

 

 

 

 

 

 

NEAX IPS DM

 

430(W) x 365(D) x 88(H) mm

 

Approximately 7Kg / MODULAR

 

 

 

NEAX IPS DML

 

 

 

 

CHASSIS (when all slots are

 

 

 

NEAX IPS DMR

 

 

 

 

occupied)

 

Page 3- 20

UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide

 

Issue 6