Chapter 11 Open Application Interface

OpenWorX: Multiple CCIS Node Configuration

OpenWorX is capable of hosting applications for multiple UNIVERGE NEAX 2000 IPS systems on a single server. All instances of this require a viable OAI connection between the

OpenWorX server and the UNIVERGE NEAX 2000 IPS. See the bandwidth requirements list previously in this chapter to make sure your connection is sufficient.

The applications once equipped with the remote TCP/IP connection and multi-node software

operate as if they are in a single UNIVERGE NEAX 2000 IPS, except where noted below.

BAS: CCIS Network Information

The Business Attendant System can run in a CCIS network environment with the following limitations. Calls transferred from the BAS Client across a CCIS Link will not recall to the BAS operator. Using multi-node capabilities, the operator can now view station data via the directory or speed dials to extensions in other IPS systems. The other IPS systems must have OAI and a TCP/IP connection back to the OpenWorX server. Additional OpenWorX software is also required per IPS to be added on the server.

Business Receptionist: CCIS Network Information

The Business Receptionist can run in a CCIS network environment with the following limitations.

Calls transferred from the Business Receptionist across a CCIS Link will not recall to the operator.

The Dterm across a CCIS Link cannot be monitored by the Business Receptionist system and the monitored speed dials and status checks in the directory will not function for those extensions.

The system will force supervised transfers to CCIS extensions to ensure callers do not get transferred to a busy remote extension.

The message-waiting lamp cannot be controlled on a remote Dterm.

Note: Business Receptionist does not have the same multi-node capability that BAS does

OAI Application Software Development

For users wishing to develop their own applications, NEC offers a complete library of development tools. For further information, contact the OAI Product Manager.

System Specifications

Required Equipment for OAI

Equipment

Description

 

Qty

 

 

Remarks

 

PN-CP24-C (MP)

MP Card

1

 

 

One card per system Mount on

 

 

 

1

 

 

PIM0

 

PZ-M606-A (ETHER)

Ethernet Control Card

 

 

Mount on MP card One card per

 

 

 

 

As

 

 

MP

 

10BASE-T Cable

10BASE-T/100BASE-TX

 

 

 

Cable length:

 

 

Cable between Ethernet

 

required

 

 

Maximum 100 m (328 ft.)

 

100BASE-TX Cable

Card and LAN

 

 

 

 

 

 

UNIVERGE NEAX 2000 IPS Request for Proposal (RFP) Reference Guide

Page 11-17

Issue 6

 

Page 223
Image 223
NEC 2000 IPS OpenWorX Multiple Ccis Node Configuration, OAI Application Software Development, BAS Ccis Network Information