Chapter 3 System Highlights

System Specifications

AC Power Requirements

Description

Specifications

AC Input Voltage

90 to 132Vac or 180 to 264Vac; 47 to 64Hz

AC Input Current

3.5A(at 100V), 2.0A(at 200V)

AC Power Consumption / Thermal Output (Maximum)

 

Description

 

 

AC Power Consumption (KVA)

 

 

Thermal Output (BTU)

 

 

 

 

100V

 

 

200V

 

 

100V

 

 

200V

 

 

 

 

 

 

 

 

 

 

 

 

 

1-PIM

 

0.35

 

0.40

 

1,195

 

1,365

 

 

2-PIM

 

0.70

 

0.80

 

2,389

 

2,730

 

 

3-PIM

 

1.05

 

1.20

 

3,584

 

4,096

 

 

4-PIM

 

1.40

 

1.60

 

4,778

 

5,461

 

 

5-PIM

 

1.75

 

2.00

 

5,973

 

6,826

 

 

6-PIM

 

2.10

 

2.40

 

7,167

 

8,191

 

 

7-PIM

 

2.45

 

2.80

 

8,362

 

9,556

 

 

8-PIM

 

2.80

 

3.20

 

9,556

 

10,922

 

Battery Requirements

 

Description

 

 

Specifications

 

 

Max. Battery Capacity

 

 

260AH per 4 PIM (65AH (12V) x 8)

 

 

DC Input Voltage for Battery

 

 

-24V

 

 

Built-in Battery Requirements

 

 

3.4AH (12V) x 2 (approx. 30min. backup)

 

 

Physical Size of Built-in Battery

 

 

133(W) x 60(H) x 67(D) mm

 

 

(one 12V battery)

 

 

 

 

 

 

 

 

Operating Environment

Description

Specifications

Ambient Temperature

0° to 40° Celsius

Relative Humidity

Max. 90% (non-condensing)

Electrical Characteristics (Central Office Trunk)

 

Description

 

 

Specifications

 

 

Insulation Resistance

 

 

15 mega-ohms or more at 100Vdc

 

 

DC Resistance

 

 

On-hook conditions: 30 mega-ohms

 

 

 

 

Off-hook conditions: 1,700 ohms

 

 

 

 

 

 

 

 

 

 

On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)

 

 

Impedance

 

 

8 kilo-ohms (at 24Hz)

 

 

 

 

 

Looped conditions: 600 ohms

 

 

Leak Current

 

0 mA at on-hook conditions

 

Page 3- 16

UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide

 

Issue 6

Page 64
Image 64
NEC 2000 IPS manual System Specifications