Chapter 3 System Highlights
Page 3- 16 UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide
Issue 6
System Specifications
AC Power Requirements
Description Specifications
AC Input Voltage 90 to 132Vac or 180 to 264Vac; 47 to 64Hz
AC Input Current 3.5A(at 100V), 2.0A(at 200V)
AC Power Consumption / Thermal Output (Maximum)
AC Power Consumption (KVA) Thermal Output (BTU)
Description 100V 200V 100V 200V
1-PIM 0.35 0.40 1,195 1,365
2-PIM 0.70 0.80 2,389 2,730
3-PIM 1.05 1.20 3,584 4,096
4-PIM 1.40 1.60 4,778 5,461
5-PIM 1.75 2.00 5,973 6,826
6-PIM 2.10 2.40 7,167 8,191
7-PIM 2.45 2.80 8,362 9,556
8-PIM 2.80 3.20 9,556 10,922
Battery Requirements
Description Specifications
Max. Battery Capacity 260AH per 4 PIM (65AH (12V) x 8)
DC Input Voltage for Battery -24V
Built-in Battery Requirements 3.4AH (12V) x 2 (approx. 30min. backup)
Physical Size of Built-in Battery
(one 12V battery) 133(W) x 60(H) x 67(D) mm
Operating Environment
Description Specifications
Ambient Temperature 0° to 40° Celsius
Relative Humidity Max. 90% (non-condensing)
Electrical Characteristics (Central Office Trunk)
Description Specifications
Insulation Resistance 15 mega-ohms or more at 100Vdc
DC Resistance On-hook conditions: 30 mega-ohms
Off-hook conditions: 1,700 ohms
Impedance
On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)
8 kilo-ohms (at 24Hz)
Looped conditions: 600 ohms
Leak Current 0 mA at on-hook conditions