Chapter 14 Common Channel Inter-Office Signaling (CCIS)

Required Equipment

Required Equipment for Digital CCIS

EQUIPMENT

FUNCTIONAL

FUNCTION

NAME

NAME

 

PN-24CCTA

CCT

CCIS (1.5 Mbps) Trunk Card

 

 

Provides a built-in Common Channel Handler (CCH) of CCIS.

 

 

 

PN-24DTA-C

DTI

T1 Digital Trunk Interface (1.5 Mbps) Card

 

 

Accommodates 24-channel PCM digital lines.

 

 

 

PN-30DTC-C

DTI

E1 Digital Trunk Interface (2 Mbps) Card

 

 

Accommodates 30-channel PCM digital lines.

 

 

 

PN-SC00

CCH

Common Channel Handler Card

 

 

Transmits/receives signals on the common signaling channel of

 

 

CCIS.

 

 

 

PN-M10

M10

Optical Fiber Interface Card

 

 

Provides optical fiber interface for T1/E1 Digital Trunk Interface

 

 

(1.5 M/2 Mbps) Line length: 6.2 miles (10 km) or less

 

 

Line coding: CMI

 

 

 

Required Equipment for Analog CCIS

EQUIPMENT

FUNCTIONAL

FUNCTION

NAME

NAME

 

PN-SC00

CCH

Common Channel Handler Card

 

 

Transmits/receives signals on the common signaling

 

 

channel of CCIS.

 

 

 

PN-2ODTA

ODT

2-line Out Band Dialing Trunk Card

 

 

Used as either a 2-wire E&M trunk or a 4-wire E&M

 

 

trunk.

 

 

Equipped with –48V DC-DC on-board power supply.

 

 

Both Circuits 0 and 1 must be set to the same

 

 

purpose

 

 

(2-wire or 4-wire) in one card.

 

 

 

Required Equipment for CCIS Networking via IP

Description

Remarks

CCIS via IP (non Peer-to-Peer)

 

SPN-IPTB

Network Interface:

 

ETHER/FAST ETHER

SPN-4VCTI

Codec Card for IP Trunk

CCIS via IP (Peer-to-Peer)

 

PZ-M606-A

On board Ethernet Interface Card

 

(ETHERNET TCP/IP)

SPN-8IPLA IP PAD-C

IP Interface card for IP Pad

PZ-24IPLA

24-channel daughter board for 8IPLA

UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide

Page 14-19

Issue 6

 

Page 297
Image 297
NEC 2000 IPS manual Required Equipment for Digital Ccis, Required Equipment for Analog Ccis, Equipment Functional Name