Chapter 5 Station Equipment
Page 5- 2 UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide
Issue 6

Inaset

ITR-240G-1 (3” gray scale LCD and 16 programmable keys)
ITR-320C-1 (5.1” color LCD and 32 programmable keys)
ITR-320G-1 (5.1” gray scale LCD and 32 programmable keys)

Wireless Handset

Dterm PSIII

Dterm IP Soft Phones

Dterm SP20

Dterm SP30

Dterm Extenders

Dterm Extender (Analog)

Analog Terminals

NEC offers three distinct analog terminals.

Descriptions of the Analog Terminals

Description Remarks
DTR-1-1 (WH) TEL
DTR-1-1 (BK) TEL
Fully modular with Redial key, Flash key, Message Waiting lamp, Data Jack
and Ring/Handset Receive Volume.
DTR-1HM-1 (WH) TEL
DTR-1HM-1 (BK) TEL
Fully modular with Redial key, 'Flash' key, Message Waiting Lamp, Data Jack,
eight programmable Feature/Speed Dial keys and Ring/Handset Receive
Volume.
DTH-1-1 (BK) TEL
Fully modular with Redial key, 'Flash' key, Mute Key, Message Waiting Lamp,
Data Jack, four programmable Feature/Speed Dial keys and Ring/Handset
Receive Volume

Line Conditions of the Analog Terminals

Terminal Type Card Type Cable Length* (Cable 0.5/24 AWG)
PN-4LCD-A (max. 600 ohms loop resistance) Approximately: 1.43km (.88 miles)
PN-8LCAA (max. 600 ohms loop resistance) Approximately: 1.43km (.88 miles)
PN-AUCA (max. 2500 ohms loop resistance) Approximately 12.29km (7.63 miles)
DTR-1-1
DTR-1HM-1
DTH-1-1
PN-4LLCB (max. 2500 ohms loop resistance) Approximately 12.29km (7.63 miles)
Note: *Cable length is based on the diameter of the cable and the terminal impedance.