Millenium™ RO System by GE Osmonics

1.10.4

Dimensions

 

 

Vertical Cabinet

Horizontal Cabinet

Height

25 ½ inches

8 inches

Depth

15 inches

15 inches

Width

8 inches

25½ inches

Weight – Operating – 55 lbs.

1.10.5Membrane Performance Characteristics

Salt rejection (TF Membranes):

95% minimum at initial testing at factory.

Test Solution:

Inlet water 1000 PPM NaCl

Conductivity:

2000 micro mhos-cm

Operating Pressure:

190 PSI, ±10 PSI

Product Back pressure:

0 PSI

1.10.6Environmental Requirement

 

Minimum

Maximum

Ambient Temperature

4°C (39°F)

32°C (90°F)

Storage Temperature

2°C (36°F)

32°C (90°F)

Altitude

N/A

10,000 feet

CAUTION:

This equipment must not be allowed to freeze. Irreparable harm to various components, including RO membranes may result.

NOTE:

The user/operator should recognize that moisture can be caused by condensation and is not necessarily an equipment leak. This equipment will function in the presence of condensation.

1.11Disposal

Disposal of this product or parts must be carried out according with local disposal codes.

14693e – 31 Mar 03

1 - 13

General Information