Safety Instructions

IMPORTANT SAFETY INSTRUCTIONS.

READ ALL INSTRUCTIONS BEFORE USING.

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS

WARNING!

When using electrical appliances, basic safety precautions should be followed, including the following:

SAFETY PRECAUTIONS

Tips Operating Instructions Installation Instructions

Use this appliance only for its intended purpose as described in this Owner’s Manual.

Read all the instructions before using the appliance.

To reduce the risk of injury, close supervision is required when an appliance is used near children.

Do not put fingers or hands into a waste disposer.

Turn the power switch to the off position before attempting to clear a jam or remove an object from the disposer.

When attempting to loosen a jam in a waste disposer, use a long wooden object such as a wooden spoon or the wooden handle of a broom or mop.

When attempting to remove objects from a waste disposer, use long-handled tongs or pliers. If the disposer is magnetically actuated, use only nonmagnetic tools.

To reduce the risk of injury by materials that may be expelled by a waste disposer, do not put the following into a disposer:

a)Clam or oyster shells.

b)Caustic drain cleaners or similar products.

c)Glass, china or plastic.

d)Large whole bones.

e)Metal, such as bottle caps, tin cans, utensils or aluminum foil.

f)Hot grease or other hot liquids.

g)Whole corn husks.

When not operating a disposer, leave the drain stopper in place to reduce the risk of objects falling into the disposer.

For proper grounding instructions see the ELECTRICAL CONNECTION portion of this manual.

Troubleshooting

WARNING!

HOW TO CONNECT ELECTRICITY

If you are not familiar with electrical power and procedures, call a qualified electrician.

Consumer Support

DANGER: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance if it will not fit the outlet; have a proper outlet installed by a qualified electrician.

For Models Equipped with a Grounded Cord:

GROUNDING INSTRUCTIONS: This appliance must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

2

Page 2
Image 2
GE GFC500F, GFB1000F, GFC700F, GFC1000F, GFB700F owner manual Consumer Support, For Models Equipped with a Grounded Cord

GFB700F, GFC1000F, GFC500F, GFC700F, GFB1000F specifications

General Electric (GE) has established itself as a leader in the aviation and energy sectors, offering an impressive array of high-performance gas turbines. Models like the GE GFB1000F, GFC700F, GFC500F, GFC1000F, and GFB700F stand as testaments to the company’s commitment to innovative engineering and advanced technology. These turbines are designed to deliver exceptional efficiency, reliability, and flexibility, catering to various industrial applications.

The GE GFB1000F turbine is characterized by its efficiency and power output, making it suitable for both base load and peak load applications. It features advanced aerodynamics and materials technology that allow it to operate at high temperatures, resulting in increased performance. The turbine also incorporates digital controls for enhanced operational efficiency and reliability.

The GFC700F model is known for its adaptability in various operational environments. It boasts a robust design that can handle fluctuating load demands without compromising efficiency. The GFC700F integrates advanced combustion technology, which minimizes emissions and ensures compliance with stringent environmental regulations.

For lower output needs, the GFC500F turbine offers a highly efficient solution with a compact footprint. Its design emphasizes ease of maintenance and operational flexibility, making it an ideal choice for smaller power plants and industrial applications. The GFC500F utilizes a simple cycle configuration, allowing for quick start-up times and operational adaptability.

The GFC1000F serves as a middle ground, delivering a balanced mix of efficiency and power for medium to large-scale applications. It features advanced sensor technology and digital controls that optimize performance in real-time, ensuring maximum output while minimizing fuel consumption.

Finally, the GFB700F represents a versatile option with a focus on flexibility and investment protection. This turbine supports a wide range of fuels and operational modes, enhancing its appeal to customers seeking a versatile energy solution. Its advanced monitoring systems allow for proactive maintenance strategies, further reducing downtime and operational costs.

Collectively, these gas turbines from GE reflect the company’s forward-thinking approach, harnessing cutting-edge technology to meet the ever-evolving demands of the energy sector. Their shared focus on efficiency, reduced emissions, and operational flexibility positions them as frontrunners in sustainable energy generation.