GE GFC1020 Installation Instructions 4 CONNECTING DISPOSER TO SINK FLANGE, Attach To Sink Flange

Models: GFC720 GFC320 GFB760 GFC520 GFC1020 GFC530

1 24
Download 24 pages 15.41 Kb
Page 7
Image 7
Installation Instructions

Installation Instructions

4CONNECTING DISPOSER TO SINK FLANGE

1ATTACH TO SINK FLANGE

3LOCK MOUNT RING

Line up the disposer under the sink flange. Guide the hopper projections into the mount ring slots. Turn the mount ring about 1/4″ to the right so that the disposer is temporarily supported.

Mount

Ring Slot 1ATTACH TO SINK FLANGE3LOCK MOUNT RING

Hopper

Projection

Turn the mount ring slowly to the right until it locks up tight. Hopper projections must be to the extreme left of the mounting slots. If the mount ring is hard to turn, you may add a small amount of petroleum jelly or liquid soap to the hopper projection. Run water and check for leaks.

2LINE UP WITH OUTLET PIPE

Turn the mount ring and the disposer until the disposer discharge elbow lines up with the outlet pipe (see page 8).

Discharge 2LINE UP WITH OUTLET PIPE

Elbow

Outlet Pipe 4CHECK FOR LEAKS

Locking Detail

Hopper Projection in

“Supported” Position

Hopper Projection

Mounting Slot

Mount

in “Locked” Position

Ring

4CHECK FOR LEAKS

Check the unit for leaks 24 hours after installation and first operation.