THIS DISHWASHER IS PROGRAMMED WITH A SERVICE MODE TO AID THE TECHNICIAN IN TROUBLESHOOTING THE DISHWASHER. EACH COMPONENT MAY BE CYCLED TO DETECT IF IT IS FUNCTIONING CORRECTLY. COMPO- NENTS ARE CYCLED BY PRESSING KEYPADS TO THE LEFT OF THE START/RESET KEYPAD. USE THE MATRIX BELOW TO DETERMINE HOW TO CYCLE EACH COMPONENT.

TO ENTER SERVICE MODE :

PRESS KEYPAD #9 AND KEYPAD #3 SIMULTANEOUSLY FOR 3 SECONDS.

TO EXIT SERVICE MODE :

PRESS THE START/RESET KEYPAD AT ANYTIME TO EXIT.

Service Mode Test Matrix*

Keypad

Description

Time in Seconds**

9

Activates Water Valve

50

 

 

 

8

Activates Heating Element

600

 

 

 

7

Activates Main Pump

75

 

 

 

6

Activates Detergent Module

60

 

 

 

5

Activates Drain Pump

75

 

 

 

3

Activates the following in order:

3 seconds each cycle

 

Status LEDs; Wash LEDs;

 

 

Start/Reset and Option LEDs

 

 

 

 

2

Opens Active Vent

 

 

 

 

1

Closes Active Vent

 

 

 

 

START/RESET

Used to EXIT Service Mode

 

 

 

 

*NOTE: After 15 minutes of inactivity, the service mode will automatically turn off.

**NOTE: Component will be activated for indicated time. Component may be deactivated by pressing the same keypad that was pressed to activate the component.

TO ENTER F-1 TEST CYCLE:

1.Power up unit.

2.Close detergent cup and latch door.

3.Press KEYPAD #9 and KEYPAD #8 simultaneously for one second. The control will then step through the test automatically.

TO EXIT F-1 TEST CYCLE:

1.Press START/RESET to skip each step until the end.

2.The control will then exit the test cycle, pump out any remaining water and return to normal operation.

F-1 TEST CYCLE MATRIX

STEP

 

ACTION

LED DISPLAY

DESCRIPTION

 

1

 

Start

SENSING and WASHING flash

 

 

 

 

for 10 seconds

 

 

 

 

 

 

2

 

Model Number Display

Combination of KEY 1 (LOCK)

Use KEY 1 (MS3) and DELAY

 

 

 

and DELAY START 1, 2 or 3

START LEDs to display model

 

 

 

 

number in binary for 5 seconds

 

 

 

 

 

3

 

Illuminate Display

All LED’s

Energize all LEDs for 5 seconds.

4

 

Trip Detergent & Fill

DRYING, SANITIZED

Trip the detergent cup. Energize

 

 

 

 

the water valve for 50 seconds.

 

 

 

 

 

5

 

Fill & Circulate

RINSING

Energize the water valve and

 

 

 

 

main pump for 10 seconds.

 

 

 

 

Close the active vent.

 

 

 

 

 

6

 

Circulate & Heat

RINSING, SANITIZED

Energize the main pump and

 

 

 

 

heater for 60 seconds.

 

 

 

 

 

7

 

Calibration

SENSING

All relays and LEDs will be off

 

 

 

 

while the processor calibrates

 

 

 

 

the turbidity sensor.

 

 

 

 

 

8

 

Circulate & Drain

RINSING, DRYING

Energize the main pump and

 

 

 

 

auxiliary pump to evacuate water

 

 

 

 

from the unit for 10 seconds.

 

 

 

 

 

9

 

Circulate

RINSING, DRYING, SANITIZED

Energize the main pump to

 

 

 

 

circulate water in the unit for

 

 

 

 

50 seconds.

 

 

 

 

 

10

 

Trip Rinse Agent &

WASHING

Trip the rinse agent. Read

 

 

Self diagnostics

 

Turbidity Sensor. Read tub

 

 

 

 

temperature sensor. Read

 

 

 

 

EEPROM. If diagnostics or turbidity

 

 

 

 

errors occur, energize the beeper

 

 

 

 

and flash LEDs (see below).

 

 

 

 

 

11

 

Fill

WASHING, SANITIZED

Energize the water valve for 50

 

 

 

 

seconds.

 

 

 

 

 

12

 

Fill & Circulate

WASHING, DRYING

Energize the water valve and main

 

 

 

 

pump for 3 seconds.

 

 

 

 

 

13

 

Circulate & Heat

WASHING, DRYING, SANITIZED

Energize the main pump and

 

 

 

 

heater for 60 minutes.

 

 

 

 

 

14

 

Auxiliary Pump

All LED’s

Energize all LEDs and the auxiliary

 

 

 

 

pump to evacuate water for 5

 

 

 

 

seconds. Open the active vent.

 

 

 

 

 

15

 

Auxiliary Pump

WASHING, RINSING,

Energize the auxiliary pump to

 

 

 

SANITIZED

evacuate water from the unit for

 

 

 

 

70 seconds.

 

 

 

 

 

16

 

Exit

 

 

NOTE: DELAY START 1, 2 & 3 represent the leftmost, middle and rightmost DELAY START LEDs, respectively.

In STEP 10 of the F1 Test Cycle: If the control senses a turbidity sensor error, the control will flash the SENSING LED. If the control senses a tub temperature sensor error, then the control will flash the HEATED DRY LED. If the control senses an EEPROM error, then the control will flash the LOCK LED. If any of these diagnostic errors are detected, the cycle will not advance to STEP 11 until a key is pressed.

Page 3