About the water softener system.

Service: Electronic Demand Time Features and Service

ERROR CODE

 

 

 

 

 

DISPLAYED

ERR 01

ERR 02

ERR 03

ERR 04

ERR 05

 

 

 

 

 

 

POSSIBLE DEFECT

• Motor

•Position

•Motor

•Position

•Control

 

inoperative

switch

inoperative

switch or

 

 

 

 

or wiring

wiring

 

 

 

 

harness

harness

 

 

• Wiring

•Control

•Control

•Control

 

 

harness or

 

 

 

 

 

connection

 

 

 

 

 

to switch

 

 

 

 

 

• Position

 

 

 

 

 

switch

 

 

 

 

 

• Control

 

 

 

 

 

 

 

 

 

 

To remove an error code: 1. Unplug transformer.

2.Correct defect.

3.Plug transformer in.

4.Wait for at least 6 minutes. The error code will return if the reason for the error code was not corrected.

Service: Timer/Softener, Service Checkout Procedure

If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.

VISUAL CHECKS:

1.Is there electrical power to the outlet the water softening system transformer is plugged into?

2.Is there sufficient salt in the storage tank?

3.Is the softener bypass valve directing water for soft water service?

4.Is the valve drain hose open to the drain, not more than 8above the softener, and unobstructed? If hose is above 8, see page 8, step 4.

If you do not find a problem with the visual checks, continue below.

 

 

 

CONTROL SHOWS

NO SOFT

 

 

 

 

WRONG TIME AND

WATER

 

 

 

 

DAY, AND/OR IS

 

 

 

FLASHING.

 

 

 

 

 

Electrical power was off. Reset the correct time of day.

Investigate reason for power loss.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check electrical

 

 

 

 

 

 

 

 

REPAIR AS

 

Do manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power to control

 

 

 

 

 

NO POWER

 

 

NEEDED

 

diagnostics

 

CONTROL

 

 

 

(outlet,

 

 

 

 

 

 

 

 

 

 

 

to verify

 

DISPLAY

 

 

 

transformer,

 

 

 

 

 

 

 

 

 

 

proper

 

 

 

 

 

 

 

 

 

POWER OK

 

 

CONTROL

 

BLANK.

 

 

 

power cable, all

 

 

 

 

 

 

 

 

function.

 

 

 

 

 

 

 

 

 

 

 

 

DEFECTIVE

 

 

 

 

 

 

connections).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL DISPLAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHOWS CORRECT TIME

 

 

 

Do manual

 

 

 

 

 

 

 

AND DAY AND IS

 

 

 

 

diagnostics.

 

 

 

 

 

 

 

STEADY.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16