ge.com
1. To enter diagnostics, press and hold the | Turbine Switches |
| ||||||
MODE button until (000 – |
|
|
|
|
|
|
|
|
|
|
|
| OR |
|
| ||
|
|
|
|
|
| |||
display. |
|
|
|
|
|
| ||
A The first 3 digits indicate water meter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
operation as follows: | Water Switch (B) | |||||||
■ 000 (steady) = soft water not in | Meter | |||||||
(A) | ||||||||
use…no flow through the meter. |
|
|
|
|
|
|
|
|
■000 to 199 (continual) = repeats display for each gallon of water passing through the meter.
Motor
Position
switchSensor
housing Turbine
Valve | Turbine support | |
and shaft | ||
outlet | ||
|
If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.
BThe letter (P) and dash(es) indicate POSITION switch operation. The letter appearing means the switch is
closed; the dash means the switch is open. Use the
RECHARGE (RECHARGE
CORRECT SWITCH |
|
DISPLAYS | VALVE CYCLE STATUS |
——Valve in service, fill, brining, backwash or fast rinse position.
— P | Valve rotating from one position to |
| another |
CWhile in this diagnostic screen, the following information is available and may be beneficial for various reasons. This information is retained by the computer from the first time electrical power is applied to the control.
■Press and hold the UP button to display the number of days this control has had electrical power applied.
■Press and hold the DOWN button to display the number of regenerations initiated by this control since the SR code number was entered.
2.Press the MODE button and hold in three
seconds until a Service Rating code appears in the display.
For correct water softening systemoperation, the model code must be F30 for model GXSF30H.To reset the code, press the UP or DOWN button until the correct number shows.3.Press the MODE button to return to the present time display.
If the code was changed, make ALL the timer settings.NOTE: If the control is left in a diagnostic display or a flashing display when setting times or hardness, present time automatically returns if a button is not pressed within four minutes.
17