53-WIRE INSTALLATION

53-WIRE INSTALLATION

DO NOT remove the ground strap connection.WARNING: The neutral or ground wire of the power cord must be connected

to the neutral terminal located in the center of the terminal block and the ground strap must connect the neutral terminal to the ground plate. The power leads must be connected to the lower left and the lower right terminals of the terminal block.

DO NOT remove the ground strap connection.

FOR POWER CORD INSTALLATION

A. Remove the 3 lower terminal screws from the terminal block.

B. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral)

is connected to the center lower position of the terminal block.

C. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A. Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 5/8” long.

B. Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening

and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.

C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the correct amperage and voltage.

Power Cord

Conduit

Terminal block

Terminal

(appearance

block

may vary)

 

Neutral terminal

Wire tips

 

Ground strap

 

Ground

 

plate

 

 

Conduit

Power cord

 

PROCEED TO STEP 7.

 

31-10677

64-WIRE INSTALLATION

FOR CONDUIT INSTALLATION WARNING: The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left

and the lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with the ground plate and the green ground screw.

FOR POWER CORD INSTALLATION

A. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. Cut and discard the ground strap. DONOTDISCARDANYSCREWS.

B.Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate and into the frame of the range.

C.Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A.Loosen the 3 lower terminal screws on the terminal block. Remove the ground screw and ground plate and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Strip wire to exposed tip about 5/8” long.

B.Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.

C.Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the correct amperage and voltage.

Before–Power Cord and Conduit

After–Power Cord

 

 

Ground strap

 

 

Terminal

 

Terminal

Neutral

block

or

block

terminal

 

 

Ground plate

 

 

 

Ground

 

 

(grounding to

 

 

range)

strap

Neutral

 

 

 

terminal

Ground

 

 

 

 

 

 

screw

 

 

 

After–Conduit

 

 

 

Terminal

Ground

 

 

plate

 

 

block

 

 

(grounding

 

 

 

 

 

 

to range)

 

 

Wire

 

 

 

tips

 

 

 

Ground screw

 

08-08 JR

Page 3
Image 3
GE JB988SK 5 3-WIRE INSTALLATION, 6 4-WIRE INSTALLATION, 31-10677, Before-Power Cord and Conduit, After-Power Cord