GE JVB98SH Venting Duct Information, Plan the Ductwork, Specification Created 7/03, Duct Pieces

Models: JVB98SH

1 3
Download 3 pages 57.89 Kb
Page 2
Image 2
Venting Duct Information

TM

JVB98SH – GE Profile36" Telescopic Downdraft System

Venting Duct Information

Duct PiecesEquivalent Length*

Duct Pieces

Equivalent Length*

 

1 ft. (per foot length)

3-1/4" x 10"

5 ft.

6" Round

to 6" Round

Straight

 

Transition

 

3-1/4" x 10"

1 ft. (per foot length)

6" Round

20 ft.

to 3-1/4 x 10"

Straight

 

Transitions

 

 

 

90° Elbow

 

6"

15 ft.

3-1/4" x 10"

12 ft.

to 6" Round

°

 

Transition

 

90 Elbow

 

90° Elbow

 

 

 

 

6"

9 ft.

6" Round

21 ft.

 

 

 

45° Elbow

 

Wall Cap

 

 

with Damper

 

 

 

 

3-1/4" x 10"

16 ft.

3-1/4" x 10"

27 ft.

Wall Cap

90° Elbow

 

with Damper

 

3-1/4" x 10"

5 ft.

6" Round

20 ft.

Roof Cap

 

 

 

45° Elbow

 

 

 

3-1/4" x 10"

24 ft.

6" Round

24 ft.

Roof Vent

45° Elbow

 

 

 

 

 

6" Round

 

SHOULD NOT EXCEED 100 EQUIVALENT FT.

7 ft.

*Equivalent length of duct pieces are based on actual test conducted by

to 3-1/4 x 10"

Transitions

 

GE Evaluation Engineering and reflect requirements for good venting

 

performance with a downdraft rated at 500 CFM

 

 

Specification Created 7/03

Plan the Ductwork

1. This downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Two different discharge directions are available with side-to-side adjustment for the accurate alignment of ductwork.

2. For best performance: choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall joists, wall studs, electrical wiring or plumbing for possible interference.

Right discharge

Left discharge (as shipped)

Steps to Determine Flexible Ducting’s Equivalent Length

1. Measure the actual amount of offset (Maximum 3" recommended). The effect upon airflow is dependent upon the amount of offset.

2. Calculate the equivalent ducting allowances using: (__in. offset) x (14 Ft. per inch)

=__Ft. equivalent length.

1. Ensure that the total equivalent length of ducting does not exceed the maximum recommendation of 150 feet.

Listed by

Underwriters

RLaboratories

For answers to your Monogram,® GE Profileor

GE® appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center® service, 800.626.2000.

220961

Page 2
Image 2
GE Venting Duct Information, Plan the Ductwork, JVB98SH - GE Profile 36 Telescopic Downdraft System, Duct Pieces