GE Spacemaker® Over-the-Range Microwave Oven
Dimensions and Installation Information (in inches) |
|
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the | Optional Accessories (Available at additional cost) |
following carefully. |
|
Exhaust Connection: The hood exhaust has been designed to mate with a standard
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct | Equivalent Feet |
A. |
|
Transition Adaptor | 5 ft. |
|
|
B. Wall Cap | 40 ft. |
|
|
C. 90° Elbow | 10 ft. |
|
|
D. 45° Elbow | 5 ft. |
|
|
E. 90° Elbow | 25 ft. |
|
|
F. 45° Elbow | 5 ft. |
|
|
G. Roof Cap | 24 ft. |
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
12" Filler Panel Kits
15" Filler Panel Kits
When replacing a 36" or
42" range hood, this kit fills in the additional width to
provide a custom
for
Filter KitsJX81– Recirculating Charcoal Filter KitTo be used when the Spacemaker microwave oven cannot be vented to the outside.
Listed by
Underwriters
Laboratories
Specification Revised 8/07 | 340121 |