GE LMAB1240ST Interlock Continuity Test, A. Primary Interlock Switch Test, C. Monitor Switch Test

Models: LMAB1240ST

1 35
Download 35 pages 26.6 Kb
Page 18
Image 18
INTERLOCK CONTINUITY TEST

INTERLOCK CONTINUITY TEST

WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS. ALL THESE SWITCHES MUST BE REPLACED AT THE SAME TIME.

TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH TYPE NO. SZM-V 16-FA-62, VP-532A-OF OR V-5220Q FOR MONITOR SWITCH TYPE NO. SZM-V 15-FA-63, VP-533A-OFF OR SECONDARY SWITCH

A. PRIMARY INTERLOCK SWITCH TEST

When the door is opened slowly, an audible click should be heard at the same time or successively at intervals and the latches should activate the switches with an audible click.

If the latches do not activate the switches when the door is closed, the switches should be adjusted in accordance with the adjustment procedure. Disconnect the wire lead from the primary switch. Connect the ohmmeter leads to the common (COM) and normally open (NO) terminal of the switch. The meter should indicate an open circuit in the door open condition. When the door is closed, the meter should indicate a closed circuit.

When the primary switch operation is abnormal, make the necessary adjustment or replace the switch with the same type of switch.

B. SECONDARY INTERLOCK SWITCH TEST

Disconnect the wire lead from the secondary switch.

Connect the ohmmeter leads to the common (COM) and normally open (NO) terminals of the switch. The meter should indicate an open circuit in the door open condition. When the door is closed, the meter should indicate a closed circuit. When the secondary switch operation is abnormal, make the necessary adjustment or replace the switch with the same type of switch.

C. MONITOR SWITCH TEST

Disconnect the wire lead from the monitor switch. Connect the ohmmeter leads to the common (COM) and normally closed (NC) terminals of the switch. The meter should indicate closed circuit in the door open condition. When the door is closed, the meter should indicate an open circuit. When the monitor switch operation is abnormal, replace with the same type of switch.

NOTE: After repairing the door or the interlock system, it is necessary to do this continuity test before operating the oven.

COMPONENTS

 

TEST PROCEDURE

RESULTS

 

SWITCHES

Check for continuity of the

Door

Door

(Wire leads removed)

switch with an Ohm-meter

open

closed

 

Primary

NO

 

 

 

Switch

COM

 

 

 

 

 

 

 

Monitor

NC

 

 

 

COM

 

 

 

Switch

 

 

 

 

 

 

 

Secondary

NO

 

 

 

Switch

COM

 

 

 

 

 

 

 

NOTE : After checking for the continuity of switches, make sure that they are

 

connected correctly.

 

 

5-7

Page 18
Image 18
GE LMAB1240ST Interlock Continuity Test, A. Primary Interlock Switch Test, B. Secondary Interlock Switch Test, Components