GE RAK147P1. RAL163P1 installation instructions Hold and Temporary Override, Day/Time Setting Mode

Models: RAK147P1. RAL163P1

1 20
Download 20 pages 50.19 Kb
Page 6
Image 6

Safety Instructions

Operating Instructions

Instructions

Using your thermostat.

Hold and Temporary Override

Hold is the permanent bypass of program temperature

setpoints. Manual release is required to return to active program mode.

Press HOLD/RETURN in NORMAL mode for hold. The current setpoint temperature will be used. The HOLD icon will be displayed and the program numbers will be cleared.

The HOLD temperature setpoint can be changed by following

the directions for changing the normal temperature in the previous section.

To release the hold, press HOLD/RETURN again in NORMAL mode to return to programmed operation. The HOLD icon will disappear.

Temporary override is the temporary change of the setpoint temperature until the next program time. Refer to the previous section on changing temperature setpoints for information on

adjusting the temperature.

To release temporary override before the next setpoint comes, press HOLD/RETURN twice in NORMAL mode (the first press will

Figure 10: ‘HOLD’ Displaychange to hold and the second press will release the hold and temporary override).

Day/Time Setting Mode

Installation

Troubleshooting Tips

Figure 11: Changing Time and Date Display

6

In NORMAL mode, press DAY/TIME to enter the DAY/TIME SETTING mode. The LCD will be cleared except for the time and day of week indicator.

When the hour is flashing, press (increase setting) or (decrease setting) to adjust hour.

Press DAY/TIME again. Minutes will be flashing. Press or to adjust minutes.

Press DAY/TIME again. The day will be flashing. Press or to adjust day.

Press DAY/TIME again. The thermostat will return to NORMAL mode.

When adjusting the day or time, press and hold or for

2 seconds for fast advance. During fast advance, the data will stop flashing.

At any time you may press the HOLD/RETURN button or wait 5 seconds to return to NORMAL mode.

The clock seconds will be reset to zero whenever time is changed. The clock seconds will not be affected if only the day is changed.

The time display will be frozen in DAY/TIME setting mode. However, the internal clock is still running. If nothing is changed, then the frozen time will be replaced by the internal clock when you return back to the NORMAL mode.

Page 6
Image 6
GE RAK147P1. RAL163P1 installation instructions Hold and Temporary Override, Day/Time Setting Mode

RAK147P1. RAL163P1 specifications

The GE RAK147P1 and RAL163P1 are advanced technologies in the field of electrical and electronic components, notably recognized for their reliability and performance in various applications. Both models are part of General Electric's extensive line of products designed to meet the demands of modern industrial environments.

The RAK147P1 has a compact design that allows for easy installation and integration into existing systems. It boasts a robust construction that is resistant to harsh operational conditions. One of its standout features is its high efficiency in energy consumption, making it an environmentally friendly option. The technology employed in this model ensures optimal energy usage, reducing operational costs and carbon footprint for industries reliant on heavy machinery.

The RAK147P1 also incorporates sophisticated digital control systems that enhance its functionality. These systems provide real-time monitoring and diagnostics, allowing operators to maintain optimal performance and promptly address any issues that may arise. Additionally, the model supports a wide range of input and output configurations, making it versatile for different applications in manufacturing, automation, and energy management.

On the other hand, the RAL163P1 is designed with an emphasis on enhanced productivity and connectivity. It features advanced communication protocols, enabling seamless integration with other smart devices in an industrial setting. This model supports IoT (Internet of Things) applications, allowing for remote monitoring and control, which is crucial for industries seeking to optimize their operational efficiency.

Both models share several key characteristics, such as high durability, temperature resilience, and compliance with stringent safety standards. They undergo rigorous testing to ensure that they perform reliably across various conditions, which is essential in sectors such as manufacturing, utilities, and transportation.

In summary, the GE RAK147P1 and RAL163P1 are exemplary products that showcase General Electric's commitment to innovation and quality. With their array of features and technologies, they cater to the evolving needs of modern industries. Their robust design, efficiency, and connectivity options position them as leading choices for businesses aiming to enhance their operational capabilities while reducing environmental impact. As industries continue to evolve, these models represent a significant step forward in the integration of advanced technologies into everyday operations.