Installation Instructions
RECOMMENDED GAS AND ELECTRIC SUPPLY LOCATION
NOTE: Recommended gas
C
D
30″
Check local codes before making connections.
2″
2″
A
|
|
|
| 30″ Min. |
|
|
|
|
| 13″ |
|
|
|
|
|
| 1/4″ | Max | 18″ Min. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| B Minimum |
| |
|
|
|
|
|
| distance to |
|
|
|
|
|
|
| walls above | |
|
|
|
|
|
| the cooktop on | |
| 12″ |
|
|
|
| each side |
|
14″ |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
| 36″ | Models | A | B | C | D |
|
|
| |||||
| 8″ |
| 20″ Wide | 203⁄8″ | 2″ | 2″ | 21⁄2″ |
3″ | 8″ |
| 24″ Wide | 243⁄8″ | 2″ | 3″ | 51⁄2″ |
| Electrical |
|
|
|
| ||
8″ |
|
|
|
|
|
| |
|
| Connection |
|
|
|
| |
|
|
|
|
|
|
| |
| 8″ |
| Area |
|
|
|
|
|
| 5″ |
|
|
|
|
Gas
Hookup
Area
A
FLEXIBLE CONNECTOR
HOOKUP (Example)
Pressure | Gas | |
regulator | ||
Flow | ||
| ||
Adapter | intoRange | |
|
Flex connector (41⁄2 ft. max.)
Adapter
Gas
1/2″ or 3/4″ Gas pipe
Installer: Inform the consumer of the location of the gas
RIGID PIPE HOOKUP (Example)
Pressure | Gas |
|
regulator |
| |
Flow |
| |
|
| |
Black iron | into |
|
|
| |
pipe 41⁄2” | Range |
|
90° Elbow |
| |
| 90° Elbow | |
|
| |
|
| Black iron |
| Nipple (may not | pipe |
|
| |
| be needed) | Union |
|
| |
|
| Nipple |
|
| Gas |
| 1/2″ or 3/4″ Gas pipe | valve |
|
|
Installer: Inform the consumer of the location of the gas
28