Speedcooking

Advantium Oven

Speedcook power level

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

 

 

 

 

 

BACK

REPEAT LAST

 

 

 

OVEN LIGHT

 

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

RECIPE

 

 

 

 

 

 

RN

TOS

ELEC

TU

T

P

TER

R

ESS TOEN

START

PAUSE

CLEAR

OFF

Advantium uses power from high intensity halogen lights and microwaves to cook food from the top, bottom and interior simultaneously to seal in moisture and flavor.

When using the pre-set menu foods, the power levels are already selected for you. However, power levels can be adjusted when cooking both pre- set menu foods and manual cooking.

Each power level gives you halogen lamp power and microwave energy for a certain percentage of the time.

U=07 Upper halogen lamp on

70% of the time.

L=07 Lower halogen lamp on

70% of the time.

M=05 Microwave on 50% of the time.

NOTE: Be careful when adjusting power levels so that you do not over- or undercook your food.

1.Press the SPEEDCOOK button and select your food (follow instructions from To use a pre-set speedcook menu).

2.When display shows ADJUST TIME or START, press the POWER LEVEL button.

3.Turn the dial clockwise to increase or counterclockwise to decrease the upper power level. Press the dial to enter.

4.Turn the dial to change the lower power level. Press the dial to enter.

5.Turn the dial to change the microwave power level. Press the dial to enter.

6.Press the START/PAUSE button or the selector dial to start cooking.

If you do not want to change one of the settings, just press the dial to move to the next selection.

Follow these general guidelines when selecting the best U=, L=, M= settings for your favorite recipes:

U =

Select a higher setting for

M = Select a higher setting to

 

thin foods requiring a golden

shorten cooking time for dense

 

brown top (example: fish fillets,

or heavy foods (example:

 

toast, boneless chicken breasts).

casseroles, whole chicken).

 

Select a lower setting for thicker

Select a lower setting for

 

foods and foods with high sugar

delicate foods (example: cakes,

 

or fat content (example: cakes,

breads, souffles) or foods

 

roasts).

requiring longer cook times

L =

Select a higher setting for thick

for tender results (example:

stew, pot roast).

 

or dense foods that may not

 

 

 

cook quickly in the center

 

 

(example: casseroles). Select

 

 

a lower setting for thin foods

 

 

(example: cookies) and foods

 

 

containing high fat or sugar

 

 

content (example: pastry,

 

 

cakes).

 

16

Page 16
Image 16
GE SCB2000, SCB2001 owner manual Speedcook power level

SCB2000, SCB2001 specifications

The GE SCB2000 and SCB2001 are advanced digital protective relay systems designed for a variety of applications in the electrical power industry. These devices are recognized for their robust capabilities in protection, control, and monitoring of electrical distribution systems.

One of the primary features of the SCB2000 and SCB2001 is their comprehensive protection functionality. They are equipped to handle overload, short circuit, and earth fault protection for transformers, motors, and feeders. The advanced algorithms incorporated in these relays allow for precise detection and isolation of faults, minimizing downtime and enhancing system reliability.

These devices leverage state-of-the-art technology, including microprocessor-based controls, which ensure high performance and flexibility. The GE SCB relays are designed for easy integration into existing systems owing to their modular architecture. This functionality supports various communication protocols, including DNP3, IEC 61850, and Modbus, enabling seamless interaction with SCADA systems and other automation frameworks.

In terms of characteristics, the SCB2000 and SCB2001 provide extensive event and fault recording capabilities. They can capture a wealth of data before, during, and after events, offering valuable insights into system performance and facilitating effective troubleshooting. The user-friendly interface, typically featuring a color LCD display, allows operators to easily access critical information and configure settings.

Safety is paramount in the design of these devices. GE has implemented comprehensive self-diagnostic features that continuously monitor the relay’s health and operational status. This ensures that any potential issues are identified and addressed proactively, further reducing the risk of system failure.

Energy efficiency is another hallmark of the SCB2000 and SCB2001 series. With their intelligent design, these relays help optimize load management and energy distribution, contributing to lower operational costs for utility providers and industrial plants alike.

In conclusion, the GE SCB2000 and SCB2001 protective relay systems stand out for their versatility, advanced protective features, and seamless integration capabilities. With a focus on reliability, safety, and efficiency, these devices empower utilities and industries to enhance their electrical systems' performance, ensuring continuous and secure operation.